RMU101
xx1300000279
Battery pack RMU with 3-pole battery contact
A
Serial measurement board (SMB), RMU 101
B
Attachment screws (2 pcs)
C
Required equipment
All spare parts are listed in
Spare parts
in
Product manual, spare parts - IRB
1600/1660
.
Note
There are different variants of SMB units and batteries. The variant with the
3-pole battery contact has longer lifetime for the battery.
It is important that the SMB unit uses the correct battery. Make sure to order the
correct spare parts. Do not replace the battery contact!
Note
Equipment, etc.
See
Spare parts
in
Product manual, spare
parts - IRB 1600/1660
.
Serial measurement unit
See
Spare parts
in
Product manual, spare
parts - IRB 1600/1660
.
Battery pack
Indoors
Cable tie
Replace only if required!
Gasket base-cover
Content is defined in section
.
Standard toolkit, IRB 140
These procedures include references to the
tools required.
Other tools and procedures may be required.
See references to these procedures in the
step-by-step instructions below.
See chapter
.
Circuit diagram
Continues on next page
168
Product manual - IRB 140
3HAC027400-001 Revision: V
© Copyright 2004-2018 ABB. All rights reserved.
4 Repair
4.6.3 Replacing the serial measurement unit and the battery pack
Continued
Содержание IRB 140
Страница 1: ...ROBOTICS Product manual IRB 140 ...
Страница 2: ...Trace back information Workspace R18 2 version a18 Checked in 2018 11 20 Skribenta version 5 3 012 ...
Страница 8: ...This page is intentionally left blank ...
Страница 46: ...This page is intentionally left blank ...
Страница 214: ...This page is intentionally left blank ...
Страница 228: ...This page is intentionally left blank ...
Страница 230: ...This page is intentionally left blank ...
Страница 244: ...This page is intentionally left blank ...
Страница 250: ......
Страница 251: ......