Product description

Product manual 2TMD042100D0003

9

5.4

Lock type and connection

Lock type

Pic

Operation type

Voltage

Wiring type

Electrical strike
lock, 12V

Power on to open

12 V

/~

Type A/B

Electrical strike
lock, 24V

Power on to open

24 V

/~

Type B

Electrical rim
lock, 12 V

Power on to open

12 V

Type A/B

Electrical
mortise lock

Power off to open

12 V

Type C

Magnetic lock

Power off to open

12/24 V

Type C

AGND

GND

NO

DC+

NC

DS

LOCK

COM

EXIT

AGND

GND

NO

DC+

NC

DS

LOCK

COM

EXIT

AGND

GND

NO

DC+

NC

DS

L OCK

COM

EXI T

+

+

+

-

-

-

PS

PS

Type A

Type B

Type C

Содержание i-HD H81365P A Series

Страница 1: ...i 2TMD042100D0003 02 12 2021 Product manual ABB i HD H81365P A Mini video outdoor station ...

Страница 2: ...7 2 5 Cavity wall installation 15 8 Commissioning 16 8 1 Configure the settings on indoor station 16 8 1 1 Outdoor station enters engineering mode 16 8 1 2 Indoor station enters engineering settings 17 8 1 3 Local device settings 18 8 1 4 Lock management 20 8 1 5 Door status detection 21 8 1 6 Sound setting 22 8 1 7 Anti flicker setting 23 8 1 8 Card mode 24 8 1 9 Set the function of pushbutton 25...

Страница 3: ...Table of contents Product manual 2TMD042100D0003 3 9 3 Deployment guideline 36 9 4 Upgrading 36 9 5 Backup Restore 36 9 6 Malware prevention solution 36 10 Notice 37 ...

Страница 4: ...on also pass on this manual along with it ABB accepts no liability for any failure to observe the instructions in this manual 2 Safety Warning Electric voltage Dangerous currents flow through the body when coming into direct or indirect contact with live components This can result in electric shock burns or even death Disconnect the mains power supply prior to installation and or disassembly Permi...

Страница 5: ...y 4 1 ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company ABB products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive...

Страница 6: ... 1 Device type Article number Product ID Product name Colour Size HxWxD Unit mm H81365P1 A 2TMA130011A0001 Mini video outdoor station 1 button IC FM Aluminum alloy 105 x 180 x 43 H81365P2 A 2TMA130011A0002 Mini video outdoor station 2 buttons IC FM Aluminum alloy 105 x 180 x 43 ...

Страница 7: ...7 5 2 Control elements No Description 1 Ring Indicator Indicator flashes slowly ringing Indicator flashes quickly busy line 2 Call indicator 3 Unlock indicator 4 Speaker and microphone integration 5 Round pushbutton module with IC card reader 4 5 1 2 3 ...

Страница 8: ... Connector for the sensor used for door status detection 2 Connector for exit button 3 Plug in clamps LOCK AGND for door opener 4 Plug in clamps COM NC NO for floating output 5 Plug in clamps DC GND for standalone power supply 6 LAN PoE 7 N A DS NC COM NO GND DC LAN 1 2 3 4 5 6 7 LOCK AGND EXIT ...

Страница 9: ... to open 12 V Type A B Electrical strike lock 24V Power on to open 24 V Type B Electrical rim lock 12 V Power on to open 12 V Type A B Electrical mortise lock Power off to open 12 V Type C Magnetic lock Power off to open 12 24 V Type C AGND GND NO DC NC DS LOCK COM EXIT AGND GND NO DC NC DS LOCK COM EXIT AGND GND NO DC NC DS LOCK COM EXIT PS PS Type A Type B Type C ...

Страница 10: ...ating voltage range 20 27 V Rating current 27 V 310 mA 24 V 350 mA Operating temperature 40 C 55 C Product dimensions 105 x 180 43 mm Camera type CMOS Camera viewing angle 104 Power supply for door opener 15 V 4A impulse max 250 mA holding Floating output for door opener 30 V 3 A IP level IP 54 IK level IK 07 ...

Страница 11: ...edge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect 2 Secure against being re connected 3 Ensure there is no vol...

Страница 12: ...Mounting Installation Product manual 2TMD042100D0003 12 7 2 Mounting 7 2 1 Preparation Use gloves to protect yourself against cuts 7 2 2 Installation height 1 5 m 5 feet ...

Страница 13: ... 7 2 3 Installation situation Note The following installation situations must be avoided without fail to ensure picture quality Direct light Direct sunlight Extremely bright picture background Highly reflective walls on the opposite side of the door station ...

Страница 14: ...ct manual 2TMD042100D0003 14 7 2 4 Flush mounted installation Product dimension Flush mounted with pre installation box 105 mm 180 mm 53 mm 174 mm 99 mm 45 mm 99 mm 174 mm 3 2 1 Screw shaft 4 Screw length 25 mm Mounting screw x 4 ...

Страница 15: ...ation Product manual 2TMD042100D0003 15 7 2 5 Cavity wall installation Product dimension Mounting 105 mm 180 mm 43 mm 90 mm 168 mm 92 mm 97 mm 120 mm 170 mm Screw shaft 4 Screw length 25 mm Mounting screw x 4 1 2 3 4 5 ...

Страница 16: ...mode Note The mini outdoor station must be in the same network with the indoor station Please follow the steps below Power up the mini outdoor station three indicators light green After a period of time three indicators light down Hold the first pushbutton for 5 s When three indicators flash green the mini outdoor station enters the engineering mode ...

Страница 17: ...ers engineering settings On the extra screen of indoor station click System to access the corresponding screen On the System settings screen click Engineering settings enter the engineering password and then click Outdoor station settings to access the corresponding screen ...

Страница 18: ...oduct manual 2TMD042100D0003 18 8 1 3 Local device settings On the Outdoor station settings screen select the device type 2nd OS 1 Location Internal With this setting 2nd OS is connected to the router in the apartment ...

Страница 19: ...oduct manual 2TMD042100D0003 19 2 Location External With this setting 2nd OS is connected to the switch outside the apartment Note The external and internal types cannot be used in mixed scenarios in the same apartment ...

Страница 20: ...reen No Function 1 Unlock type when swiping Set the lock to be released when swiping Default lock default Subsidiary lock 2 Lock type Set the lock type for the default lock and subsidiary lock Lock GND NO NC COM IP actuator 3 Time of unlock Set the time for unlock Power lock Lock GND Signal lock NO NC COM ...

Страница 21: ...n If this function is enable the outdoor station will send an alarm to the management software if the door is open longer than 120 s A sensor should first be connected to the outdoor station 2 Tamper proof alarm If this function is enabled the outdoor station will send an alarm to the management software if the outdoor station is removed from the wall ...

Страница 22: ...ume of outdoor station Click or to adjust the ringtone volume and the voice volume on the outdoor station 2 Button tone Tick the checkbox to enable button tones on the outdoor station 3 Voice prompt Tick the checkbox to enable voice prompts on the outdoor station Choose the language for the voice prompts from the drop down list ...

Страница 23: ...Commissioning Product manual 2TMD042100D0003 23 8 1 7 Anti flicker setting On the Outdoor station settings screen select the refresh rate from the drop down list ...

Страница 24: ...t manual 2TMD042100D0003 24 8 1 8 Card mode On the Outdoor station settings screen tick untick the checkbox to enable disable the function When the Safe mode is enabled ID card will not be supported by this outdoor station ...

Страница 25: ...MD042100D0003 25 8 1 9 Set the function of pushbutton On the Outdoor station settings screen click Pushbutton address setting to access the settings of the pushbuttons Note Device no should be entered if Phone guard unit is selected ...

Страница 26: ...6 8 1 10 Time sync setting On the Outdoor station settings screen If Sync time with management is selected the outdoor station will sync the time from the management software If Close time sync is selected the time and date needs to be set manually ...

Страница 27: ...Commissioning Product manual 2TMD042100D0003 27 8 1 11 Compatible mode setting On the Outdoor station settings screen the outdoor station is set to Security mode by default Compatible mode off ...

Страница 28: ...the firmware Note The outdoor station doesn t need to enter engineering mode when you want to upgrade the firmware On the Outdoor station settings screen click Firmware update select the outdoor station and the file from SD card then click OK to update the firmware ...

Страница 29: ...Commissioning Product manual 2TMD042100D0003 29 8 1 13 Viewing the version On the Outdoor station settings screen view the version information ...

Страница 30: ...Commissioning Product manual 2TMD042100D0003 30 8 1 14 Serial number On the Outdoor station settings screen view the serial number this number is used to get the signature from the management software ...

Страница 31: ...Commissioning Product manual 2TMD042100D0003 31 8 1 15 Signature On the Outdoor station settings screen view the signature ...

Страница 32: ...Commissioning Product manual 2TMD042100D0003 32 8 2 Configure the settings on PC management software Please see the product manual of ABB i HD management software for more details ...

Страница 33: ...r Create admin card Swipe card 1x Green Enter settings Swipe admin card 1x Orange After entering settings following functionalities can be implemented Function Action Unlock indicator Enroll user Swipe admin card 1x Orange flash 1x Swipe user card 1x Green Delete user Swipe admin card 2x Orange flash 2x Swipe user card 1x Green Enroll new admin Swipe admin card 3x Orange flash 3x Swipe new admin c...

Страница 34: ...ss and hold the 1st button for 3 s to enter configuration mode 3 LED flash green Press and hold the 1st button for 10 s to reset to factory default 3 LED OFF Reboot the device Door open LED red green orange cycle flash Technical data of IC card Work frequency Standard 13 56 MHz Mifare one S50 S70 Mifare desfire EV1 EV2 Note A maximum of 64 IC cards can be supported by mini outdoor station 2 Card m...

Страница 35: ...es related to such security breaches unauthorized access interference intrusion leakage and or theft of data or information Although ABB provides functionality testing on the products and updates that we release you should institute your own testing program for any product updates or other major system updates to include but not limited to code changes configuration file changes third party softwa...

Страница 36: ... decide to remove the device from system user shall reset the device to factory setting in order to remove all the configuration data and sensitive data in the device This will prevent sensitive data leak It is recommended to apply MAC filter and Rate limiter in the switch to prevent DOS attack 9 4 Upgrading Device supports firmware updates via management software a signature file will be used to ...

Страница 37: ...ed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or excerpts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB ...

Страница 38: ...nt We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or extracts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB ABB Xiamen Smart Technology Co Ltd No 881 FangShanXiEr Road Xiang An Industrial Area Torch Hi Tech Industrial Development Zone Xiamen Tel 86 592 295 9000 Fax ...

Отзывы: