ABB i-bus

®

 EIB

UP switching sensor
6115-/16-/17- 24 - 500

for UP bus coupling unit 6120 U-500

Operating instructions

only for authorized, skilled electricians with
EIB training

Содержание i-bus 6115-24-500

Страница 1: ...73 1 5824 22013 ABB i bus EIB UP switching sensor 6115 16 17 24 500 for UP bus coupling unit 6120 U 500 Operating instructions only for authorized skilled electricians with EIB training ...

Страница 2: ...IN VDE and the EIB manual of the ZVEI ZVEH Notes The covering frame supplied with the UP switching sensor item no 1721 is equipped with an inspection window fig 1 pos 2 You may use perforated sheets for labelling item no 1799 The manufacturer database of ABB is continuously supplemented and completed It stores the latest types of applications and their related descriptions If this database is not ...

Страница 3: ...Technical data Fig 1 Nominal voltage 5 V Current consumption 10 mA Environmental temperature range 5 to 45 C Fig 1 6120 U Phy Adresse 6 7 8 1 2 3 4 5 ...

Страница 4: ...es pos 5 provided in the retaining ring of the bus coupling unit Note Operator function and addressing see also operating instructions for the UP bus coupling unit may be programmed simultaneously or at different times Dismounting The application has got two relieves on its left and right hand side pos 8 where it may be dismounted from the bus coupling unit Use these relieves for otherwise only a ...

Страница 5: ...e programming key at the bus coupling unit the red programming LED will become illuminated After the physical address has been programmed the red LED will go out Write the number of the physical address on your device using a smudge proof pencil cf Fig 1 pos 3 Assign group address es Group addresses are assigned via a PC in connection with the ETS software ...

Страница 6: ...old of consumers To a 4 fold switching sensor for instance the following functions apply Key I 0 Function ON OFF LED red green Physical address F F F F Group address 0 1 0 4 These functions apply analogously to the single or 2 fold switching sensor Openthedevicewindowandchoosethedesiredapplication version At present there are two versions available ...

Страница 7: ...h has been assigned to the switching function of the rocker Example for application The LED shall indicate the current switching status of an actuator which is selected via several group addresses Version 2 The group address of the rocker s switching function and that of the integrated LED are indentical The LED will not change its colour if a data telegram has not been transmitted properly ...

Страница 8: ... in ON OFF state may be set to red or green LED function Assign a function to individual LED s or set them without any function this means that an LED which has not been assigned any function will not change its colour If a touch contact dimmer function is requested the UP bus coupling unit has to be loaded with different ABB application data applications ...