14.5
Connect the DC auxiliary power cables to the power supply
box
Preliminary requirements
•
Torque screwdriver
•
Wire cutter
•
Wire stripper pliers
•
Crimp pliers
•
•
DC auxiliary power cable.
•
Ferrules
Procedure
1. Strip the insulation from the end of
the cable (A).
2. Strip the insulation from the ends
of the wires (B) and (C). Refer to
section
3. Crimp ferrules onto the end of the
wires.
4. Loosen the screws on the terminals
(D) and (E).
5. Connect these wires:
•
0V DC wire (B) to the terminal
X1-7 (D)
•
24V DC wire (C) to the terminal
X1-5 (E)
6. Tighten the screws to the correct
torque. For the specification, refer to section
14.6
Connect the power supply feedback cable to the power
supply box
Preliminary requirements
•
Torque screwdriver
•
Wire cutter
•
Wire stripper pliers
•
Crimp pliers
•
•
Power supply feedback
cable. Refer to section
20.12.10
.
•
Ferrules
E D
B
C
A
Electrical installation of the power supply box
6AGA000007-0611-EN | 001
61
Note:
Make sure that external MCB and RCD are mounted in auxiliary
distribution board.