A155-M Uncoupled filter silencer
Fig. 41: Removing the uncoupled filter silencer
1. Secure lifting gear to filter silencer (81000).
2. Unscrew the hexagon-head screws (72054) and remove along with Verbus Ripp® wash-
ers (72053) and three safety plates (72055).
3. Remove the filter silencer (81000).