Страница 1: ...2TMD042000D0042 08 02 2021 Product manual ABB Welcome IP H81402FR Outdoor station IP touch 10 Face Recognition ...

Страница 2: ...screen 18 8 3 Entering the Settings screen 19 8 4 Engineering settings 21 8 5 Access control settings 22 8 6 System settings 24 9 Operation 27 9 1 Call a resident via keypad 27 9 2 Call guard unit 28 9 3 Releasing the lock by entering a password 29 9 3 1 Releasing the lock with a password set on the indoor station 29 9 3 2 Releasing the lock with a password set on the local outdoor station 31 9 3 ...

Страница 3: ...Table of contents Product manual 2TMD042000D0042 3 10 3 Deployment guideline 39 10 4 Upgrading 39 10 5 Backup Restore 39 10 6 Malware prevention solution 39 10 7 Password rule 39 11 Notice 40 ...

Страница 4: ...ep this manual in a safe place If you pass the device on also pass on this manual along with it ABB accepts no liability for any failure to observe the instructions in this manual 2 Safety Warning Electric voltage Dangerous currents flow through the body when coming into direct or indirect contact with live components This can result in electric shock burns or even death Disconnect the mains power...

Страница 5: ...station runs in Security mode by default to guarantee high security In Security mode this outdoor station requires a certificate issued by the management software before it can function normally Video privacy Making and saving video recordings can infringe on personal rights Always observe the applicable legal and labeling requirements for the placement and operation of video components ...

Страница 6: ...y 4 1 ABB devices All packaging materials and devices from ABB bear the markings and test seals for proper disposal Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company ABB products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive...

Страница 7: ...escription Product manual 2TMD042000D0042 7 5 Product description 5 1 Device type Article number Product ID Product name Colour Size mm H81402FR S 2TMA130011X0001 OS IPtouch 10 FR Stainless steel 408 x 278 x 35 ...

Страница 8: ...Product description Product manual 2TMD042000D0042 8 5 2 Control elements No Function 1 Camera 2 Speaker and microphone 3 IC card reader 4 Keypad 5 End strip 6 10 1 touch display 1 2 3 4 5 6 ...

Страница 9: ...ector for Wiegand output It supports 26 bits and 34 bits 3 Reset button 4 Connector for software debugging for factory use only 5 Connector for exit button 6 Connector for the sensor used for door status detection 7 Plug in clamps DC GND for power supply 8 Plug in clamps LOCK GND for door opener 9 Plug in clamps COM NC NO for floating output 10 LAN port 1 2 7 8 9 5 6 3 4 10 ...

Страница 10: ...ke lock 12V Power on to open 12 V Type A B Electrical strike lock 24V Power on to open 24 V Type B Electrical rim lock 12 V Power on to open 12 V Type A B Electrical mortise lock Power off to open 12 V Type C Magnetic lock Power off to open 12 24 V Type C GND NO DC NC LOCK COM GND NO DC NC LOCK COM GND NO DC NC LOCK COM PS PS Type A Type B Type C ...

Страница 11: ...ing temperature 20 C 55 C Camera type CMOS Camera viewing angle 90 Camera resolution ratio 1920 x 1080 pixels Ambient brightness 50000 Lux Power supply for door opener 18 V 4 A 10 ms impulse max 250 mA holding Floating output for door opener resistive load 230 V 3 A 30 V 3 A Video codec H 264 Audio codec G 711 IP level IP 54 IK level IK 05 Product dimension 408 mm x 278 mm x 35 mm ...

Страница 12: ...edge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect 2 Secure against being re connected 3 Ensure there is no vol...

Страница 13: ...Preparation Use gloves to protect yourself against cuts 7 2 2 Installation height Flush mounted installation 53 1280 1500 1431 1858 53 15 1111 1323 1417 2028 30 53 1006 1198 1487 2466 Distance and installation height unit mm 600 600 600 Distance and installation height unit mm ...

Страница 14: ...042000D0042 14 Note The following installation situations must be avoided without fail to ensure picture quality Direct light Direct sunlight Extremely bright picture background Highly reflective walls on the opposite side of the door station ...

Страница 15: ...uct manual 2TMD042000D0042 15 7 2 3 Flush mounted installation Flush mounted installat on i with pre installation box 2 A1 Without pre installation box A2 With pre installation box B 2 3 1 2 3 4 5 6 7 8 262 389 41 1 268 395 59 1 ...

Страница 16: ...Mounting Installation Product manual 2TMD042000D0042 16 7 2 4 Dismantling ...

Страница 17: ... screen closing time can be set in System settings Display Turn off the screen No Function 1 Welcome message The welcome message can be set locally or set on the management software 2 Developer information Developer information can be text or a picture It is sent from the management software 3 Bulletin Bulletins can be text or a picture A maximum of 3 bulletins are displayed on the screen and each...

Страница 18: ...Commissioning Product manual 2TMD042000D0042 18 8 2 Home screen On the welcome screen when the face is recognized or click any area on the screen to access the home screen ...

Страница 19: ...Commissioning Product manual 2TMD042000D0042 19 8 3 Entering the Settings screen In standby status on the home screen tap PIN code unlock then press engineering password to access the Settings screen ...

Страница 20: ...engineering settings The system default is 345678 This password should only be used for initial setting work and should be changed to another password It cannot be used as the actual password Note If an incorrect engineering password is entered 5 times within 2 minutes no further attempts are permitted for the next 1 minute ...

Страница 21: ...1 32 System attribute Call guard unit On default Off 2 Type of default guard unit Phone guard unit 2 Address of default guard unit 1 32 Digits of indoor station 3 digits 4 digits 3 Block digits 1 digit 2 digits 3 digits Compatible mode On Off Default Change password Enter current password Enter new password twice 1 This setting is only available when the device type is set to Outdoor station 2 Thi...

Страница 22: ...ng 4 Copy card to another outdoor station On Off default 5 Copy card to another gate station On Off default 4 Address of outdoor station 1 64 5 Address of gate station 1 32 Unlock type when swiping Default lock Subsidiary lock 11 Face recognition management 6 Enroll 1 Face recognition 2 Enter the name room no and phone no tap Enroll Building no is needed when the device type is set to Gate station...

Страница 23: ... device type is set to Outdoor station 5 This setting is only available when the device type is set to Gate station 6 When the Lift control function is enabled you need to set the current floor number 7 If this function is enabled the image from a photo or a video cannot release the lock on the outdoor station 8 The value range is 0 100 80 by default The higher value leads to a higher face matchin...

Страница 24: ...s On default Off 1 10 Data and time Time sync from sync from mgmtc Local setting 2 Set time hh mm 2 Set date yyyy mm dd Time format 12 hours 24 hours default Date format DD MM YYYY MM DD YYYY YYYY MM DD default Unlock time Lock GND 1 10 seconds NO NC COM 1 10 seconds Default lock Lock GND NO NC COM IP actuator Power lock ID range 1 32 Relay lock ID range 1 32 1 If this function is enabled the outd...

Страница 25: ...ff Bulletin On default Off Text on Welcome screen Welcome default 4 Lift settings Block no 001 999 Lift control On current floor 7 63 Off default Language Other Wiegand output Off default 26 bits 34 bits Anti flicker 60 Hz 50 Hz default Door open alarm On can be set as Local alarm Off default Temper alarm On Off default Forward to guard unit On Off default 3 On the Settings screen you can also tap...

Страница 26: ... Major version MCU version Hardware version Card version Keypad version Serial number The number is used to obtain the certificate issued by the management software Signature The value is displayed when the certificate issued is obtained successfully QR code To scan the QR code to obtain the product manual Reboot To reboot the device ...

Страница 27: ...e home screen tap Call then enter address to initiate a call When the device type is set to Outdoor station address room number e g 0101 When the device type is set to Gate station address block number room number e g 010101 Or you enter address on the keypad module to initiate a call directly ...

Страница 28: ...t Precondition On the Settings screen complete the following settings Engineering settings System attribute Call guard unit On Address of default guard unit enter the guard unit number 1 32 Call guard unit On the home screen tap Call guard unit to initiate a call ...

Страница 29: ...l Password Private password On On the System settings screen of the indoor station follow the steps below Change password Change unlock password Set a 3 8 digit password Password rule This password must not include continuously increasing or decreasing numbers e g 123456 654321 Three consecutive identical numbers are similarly not permitted e g 123444 666888 Note The indoor station should be added...

Страница 30: ... tap building number room number password followed by to release the lock Or on the keypad module When the Device type is set to Outdoor station press room number password When the Device type is set to Gate station press building number room number password followed by on the unlock screen to release the lock Wrong password If an incorrect password is entered 5 times within 2 minutes no further a...

Страница 31: ...nuously increasing or decreasing numbers e g 123456 654321 Three consecutive identical numbers are similarly not permitted e g 123444 666888 Releasing the lock On the home screen of the outdoor station tap PIN code unlock enter password followed by to release the lock Or on the keypad module you can enter password followed by on the unlock screen to release the lock Wrong password If an incorrect ...

Страница 32: ...n please see the Welcome App product manual Note The indoor station should be added to the trusted list of the outdoor station before use Releasing the lock On the home screen of the outdoor station tap PIN code unlock enter the password followed by to release the lock Wrong password If an incorrect password is entered 5 times within 2 minutes no further attempts are permitted for the next minute ...

Страница 33: ...sword in the management software For more details please see the management software product manual Releasing the lock On the home screen of the outdoor station tap PIN code unlock enter the password followed by to release the lock Wrong password If an incorrect password is entered 5 times within 25 minutes no further attempts are permitted for the next minute ...

Страница 34: ...p with an indoor station before this function is used 1 Create an unlock QR code Please see the Welcome App product manual for more details 2 Use the unlock QR code on the outdoor station Precondition On the Settings screen of the outdoor station follow the steps below Tap System settings Unlock type configuration QR code unlock enable ...

Страница 35: ...Please follow the steps below 1 On the home screen of the outdoor station tap QR code unlock a green line will be displayed on the screen and moves from top to down 2 Place the QR code on your mobile in front of the camera on the outdoor station to release the lock ...

Страница 36: ...g the lock by swiping IC cards Swipe a registered IC card on the specified area to release the lock IC card specification Operating frequency 13 56 MHz Standard ISO 14443A Support card Mifare one S50 S70 Mifare desfire EV1 EV2 Output format Wiegand 26 34 bit ...

Страница 37: ...r station the outdoor station will recognize your face and release the lock Face recognize successfully will be displayed on the screen and the voice prompt e g Door is open will be played in the same time if the Voice prompt function is enabled Or on the home screen of the outdoor station tap Face recognition unlock to initiate the face recognition ...

Страница 38: ...iable for damages and or losses related to such security breaches unauthorized access interference intrusion leakage and or theft of data or information Although ABB provides functionality testing on the products and updates that we release you should institute your own testing program for any product updates or other major system updates to include but not limited to code changes configuration fi...

Страница 39: ...iguration data and sensitive data on the device This will prevent sensitive data leak It is recommended to apply MAC filter and Rate limiter in the switch to prevent DOS attacks 10 4 Upgrading The device supports firmware updates via management software 10 5 Backup Restore None 10 6 Malware prevention solution The H81402FR device is not susceptible to malware because custom code cannot be executed...

Страница 40: ...ed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or excerpts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB ...

Страница 41: ...is document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or extracts thereof must not be reproduced transmitted or reused by third parties without prior written consent by ABB ABB Xiamen Smart Technology Co Ltd No 7 Fangshan South Road Hi tech area Torch park Xiang An District Xiamen China Tel 86 592 295 9000 Fax 86 592 562...