F-Input data
Description
Name
Bit
Octet
Type
Reserved *)
0
1
Unsigned8
(used as bits)
Reserved *)
1
Reserved *)
2
Reserved *)
3
Reserved *)
4
Reserved *)
5
Reserved *)
6
Reserved *)
7
*) The safety PLC shall set reserved bits to value 0. This ensures the compatibility with
future versions of the PROFIsafe profile where the reserved bits may be used.
*) The safety PLC must ignore the value of the reserved bits. This ensures the compatibility
with future versions of the PROFIsafe profile where the reserved bits may be used.
ABB_PS3 profile F-Output user data
This table shows the bit order of the F-Output data, which is included in the PROFIsafe
message sent to the FSPS-21 module from the safety PLC. For all the bits in the F-Output
data, one (1) means active and zero (0) non-active.
PROFIsafe frame from F-Host to F-Device
CRC 2
Control
byte
F-Output data
3 octets
1 octet
2 octets as Int16
2 octets as bits
LSB Octet n
...
MSB Octet
0
Octet 0
LSB Octet 3
MSB Octet
2
Octet 1
Octet 0
F-Output data
Description
Name
Bit
Octet
Type
1=Activate STO func-
tion, 0=Deactivate STO
STO_request
0
0
Unsigned8 (used as
bits)
1=Activate SS1-t func-
tion, 0=Deactivate SS1-
t
SS1-t_request
1
Reserved *)
2
Reserved *)
3
Reserved *)
4
Reserved *)
5
Reserved *)
6
Reserved *)
7
116 PROFIsafe
Содержание FSPS-21
Страница 1: ... OPTIONS FOR ABB DRIVES FSPS 21 safety functions fieldbus module User s manual ...
Страница 2: ......
Страница 4: ......
Страница 11: ...Further information Table of contents 11 ...
Страница 12: ...12 ...
Страница 26: ...26 ...
Страница 38: ...38 ...
Страница 42: ...42 ...
Страница 46: ...46 ...
Страница 69: ...Configuring safety PLC 1 Select safety telegram to use on slot 2 Leave slot 1 empty PROFINET IO Start up 69 ...
Страница 72: ...Switch or router ABB drive ABB drive ABB drive PLC Safety PLC 72 PROFINET IO Start up ...
Страница 86: ...86 ...
Страница 136: ... Configuring FSPS 21 with TIA14 1 Open TIA and create a new project 2 Select your CPU from the list 136 PROFIsafe ...
Страница 144: ...19 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 20 Insert values to blocks 144 PROFIsafe ...
Страница 147: ...26 In device configuration right click FSPS icon and select Assign device name PROFIsafe 147 ...
Страница 155: ...Select Addresses tab to see the correct IO addresses PROFIsafe 155 ...
Страница 169: ...6 To check the Device number of the FSPS 21 module select the General tab PROFIsafe 169 ...
Страница 178: ... starting the system does not cause any danger 178 Start up ...
Страница 186: ...186 ...
Страница 192: ...192 ...
Страница 200: ...200 ...
Страница 208: ...208 ...
Страница 212: ......