![ABB FSO-21 Скачать руководство пользователя страница 399](http://html.mh-extra.com/html/abb/fso-21/fso-21_user-manual_2728399.webp)
Configuration 399
How to configure mute time for monitoring start
Example
: The start of SLS monitoring in the SLS1 function
In this example, SLS1 function is requested from a higher speed than the SLS trip
limit.
•
With an encoder
=
20 ms
•
Without an encode
r: parameter
20 ms.
1
SLS request activated
2
Safe speed in the middle of SLS and SLS trip limits
3
SLS monitoring started. SLS indication activates (
2
Speed
Time
3
FSOGEN.33 or FSOGEN.31 = 20 ms
SLSx.14 = 1320 rpm
200.23 = 1200 rpm
SLS1 request
SLS1 indication
1