![ABB FSO-21 Скачать руководство пользователя страница 347](http://html.mh-extra.com/html/abb/fso-21/fso-21_user-manual_2728347.webp)
Configuration 347
How to configure SS1 with speed limit activated SBC, SBC before
STO
Note
: If you configure the SS1 with speed limit activated SBC, SBC before STO
function, this activates the same function in the SSE function (see section
configure SSE with speed limit activated SBC
). This does not activate
the SBC in the STO function. If necessary, configure the SBC also in the STO
function (see section
on page
). See also the note on page
Example 1:
The figure below shows an example of the SS1-t function with speed
limit activated SBC, SBC before STO set-up:
• SS1 function activated (
Version 1
)
• SS1 with time monitored ramp (
=
SS1-t
)
• SAR1 emergency ramp (
, always with the SS1
function - see section
on page
• delay for STO activation after SS1 request: 2000 ms
2000 ms
)
• automatic acknowledgement (
Automatic
)
• redundant emergency stop button connected to input
DI X113:1 & X114:1
)
• single output connected (
=
DO X114:9
)
• brake connected to redundant output, diagnostic pulses activated
DO X113:7 & X114:7
and
=
On
),
= DO X113:7 & X114:7)
• speed limit activated brake in use, speed below which the brake and STO are
activated: 180.0 rpm (
=
180 rpm
)
• delay for activating STO after brake: -300 ms (only a negative delay is possible,
the SBC is activated before STO) (
=
-300 ms
)
Содержание FSO-21
Страница 1: ... OPTIONS FOR ABB DRIVES FSO 21 safety functions module User s manual ...
Страница 4: ......
Страница 16: ...16 Safety instructions ...
Страница 34: ...34 Safety information and considerations ...
Страница 52: ...52 Overview ...
Страница 236: ...236 PROFIsafe ...
Страница 265: ...PROFIsafe 265 2 Select your CPU from the list 3 Install the FENA 21 GSDML file ...
Страница 275: ...PROFIsafe 275 20 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 21 Insert values to blocks ...
Страница 282: ...282 PROFIsafe 5 To read the diagnostic messages select the I O Device Diagnostics tab ...
Страница 286: ...286 PROFIsafe ...
Страница 304: ...304 Installation ...
Страница 400: ...400 Configuration ...
Страница 488: ...488 Verification and validation ...
Страница 506: ...506 Fault tracing ...
Страница 514: ...514 Maintenance ...
Страница 536: ...536 Technical data ...
Страница 538: ...538 Dimension drawings 3AXD50000018513 ...