Electrical connections
48
FV4000 / FS4000
D184B097U02
5.6
Functional ground/Equipotential bonding
Functional ground/equipotential bonding is implemented externally using the designated
terminal on the transmitter housing.
G00713
31
1
32
41
42
Fig. 39
1
Functional ground/equipotential bonding terminal
Functional ground connection
1.
Unscrew the screw-type terminal on the transmitter housing.
2.
Insert the fork-type cable lug for functional ground into the terminal between the two metal
tabs.
3.
Tighten the screw-type terminal.