P R E P A R I N G F O R I N S T A L L A T I O N
FOX615
Installation
21
Figure 5:
Earthing and power supply terminals of the FOX615 sub-
rack
Legend:
1
Subrack power interface connecting
- 2 x 0-volt
- 2 x U
T
(-48/-60 V
DC
)
2
Possible earthing / bonding terminals (6 mm screws)
2.3.2
Lightning and over-voltage protection
The FOX
units
provide
secondary over-voltage protection
for their inter-
faces in cooperation with external equipment.
The
primary protection
(as required for lightning protection) is implemented
external to the FOX615, normally at the connection points of the signal
cables to the outside world. Depending on the units and interfaces, the
implementation of gas discharge tubes at the external connection point is
suitable for providing such protection.
1
2