manualshive.com logo in svg
background image

OPTIONS FOR ABB DRIVES

FOCH filters

Hardware manual

Содержание FOCH

Страница 1: ...OPTIONS FOR ABB DRIVES FOCH filters Hardware manual...

Страница 2: ......

Страница 3: ...FOCH filters Hardware manual Table of contents 4 Installation 3AFE68577519 Rev G EN Original instructions EFFECTIVE 2024 03 12...

Страница 4: ......

Страница 5: ...llation 17 Contents of this chapter 17 Planning the installation 18 Mounting plate 18 Encasing 18 Electrical connections 18 Free space 19 Non enclosed IP00 filters 20 Enclosed IP22 filters 20 Clearanc...

Страница 6: ...maximum cable sizes 28 Derating 29 Ambient conditions 29 Materials 29 Disposal 30 Markings 6 Dimension drawings 32 FOCH0260 70 33 FOCH0320 50 FOCH0610 70 and FOCH0875 70 34 FOCH0260 72 35 FOCH0320 52...

Страница 7: ...0 52 FOCH0610 70 FOCH0875 70 Target audience This manual is intended for people who select plan the installation install commission and use the du dt filter Read the manual before working on the filte...

Страница 8: ...the filter by the lifting holes only Non enclosed IP00 filter Ground the filter to the protective earth PE terminal of the cabinet No separate grounding conductor is needed if there is proper galvanic...

Страница 9: ...adually erode the bearing races and rolling elements There are optional common mode filters and du dt filters available for the ABB drives The common mode filters mainly reduce bearing currents The du...

Страница 10: ...The voltage rise time can be calculated as follows t 0 8 LL du dt 100 200 300 0 0 0 5 1 0 1 5 2 0 2 5 3 0 1 s Un u d t d l m LL Un A LL Un l m du dt Un 1 s 1 0 2 0 5 0 4 0 3 0 1 5 2 5 3 5 4 5 100 200...

Страница 11: ...product data sheet 3 Degree of protection 4 Technical data 5 Serial number of format MYYWWXXXXX where S N Manufacturing plant M 16 17 18 for 2016 2017 2018 YY 01 02 03 for week 1 week 2 week 3 WW Digi...

Страница 12: ...12...

Страница 13: ...ters in series or change the motor cabling 2 1 For the ACS880 drives the data can be found either from the appropriate Technical catalog or Hardware manual The PDF files are available at www abb com d...

Страница 14: ...The filter will not overheat when these values are not exceeded and proper cooling is arranged Emax mJ Ithmax 1 A du dt filter type 200 289 FOCH0260 70 280 230 100 289 FOCH0260 72 140 230 260 445 FOC...

Страница 15: ...intermediate circuit DC voltage of the drive is Udc 1 35 UN 1 35 660 V 891 V The additional energy loss in the du dt filter is E C Udc 2 463 nF 891 V 2 184 mJ When 463 A and 184 mJ are compared to the...

Страница 16: ...16...

Страница 17: ...r technical data See chapter Dimension drawings page 31 for the dimensions Non enclosed IP00 filters can be mounted in an upright position with the output terminals up or down Other mounting positions...

Страница 18: ...in a cabinet according to the local safety requirements Electrical connections Busbars are recommended for connections to the input terminals of non enclosed IP00 filters Cables are recommended for c...

Страница 19: ...9 in 200 mm 7 87 in 200 mm 7 87 in Space required by the cabling or busbars 1 Note The temperature of the filter surfaces can exceed 150 C 302 F during operation Ensure that the motor cables are at le...

Страница 20: ...abling and the filter coil must be at least 15 mm 0 59 in Enclosed IP22 filters The distance between the input output cabling and the filter coil must be at least 50 mm 1 97 in Cooling The filters are...

Страница 21: ...fact discharged before beginning work Installing non enclosed IP00 filters Lift the filter by the lifting holes to the installation position Fasten the filter with four screws at the fastening points...

Страница 22: ...FOCH0320 52 22 Installation...

Страница 23: ...amps for the cable shields PE conductors If you have an enclosed IP22 filter you do the con nection as shown above If you have a non enclosed IP00 filter you must connect the cable shields to the PE b...

Страница 24: ...Installation illustrations of an enclosed IP22 filter FOCH0320 52 FOCH0320 52 24 Installation...

Страница 25: ...nals U1 V1 W1 The input terminals U1 V1 W1 of the filter are made of aluminium Use cable lugs suitable for aluminium busbars and joint grease to avoid corrosion and to ensure good electrical connectio...

Страница 26: ...26...

Страница 27: ...0000030047 3AXD50000030048 3AUA0000125245 68550483 68612217 68490286 Order code 500 690 690 690 500 690 UN V 445 289 880 720 445 289 IN A 22 35 15 22 22 35 L microH 520 370 630 760 520 370 Power loss...

Страница 28: ...erating use the DriveSize PC tool The value calculated for the drive applies also to its du dt filter Maximum drive output frequency 120 Hz Maximum allowed average switching frequency 3 kHz converter...

Страница 29: ...23 ft s2 max 7 m s2 23 ft s2 9 to 200 Hz sinusoidal 13 2 to 100 Hz sinusoidal 13 2 to 100 Hz sinusoid al Max 100 m s2 330 ft s2 Max 100 m s2 330 ft s2 Not allowed Shock IEC 60068 2 29 11 ms 11 ms 203...

Страница 30: ...g the EMC re quirements see the additional information concerning the drive EMC compliance IEC EN 61800 3 UL Listed mark for USA and Canada Product has been tested and evaluated against the relevant N...

Страница 31: ...Dimension drawings The dimensions are given in millimetres and inches below 6 Dimension drawings 31...

Страница 32: ...FOCH0260 70 32 Dimension drawings...

Страница 33: ...FOCH0320 50 FOCH0610 70 and FOCH0875 70 Dimension drawings 33...

Страница 34: ...FOCH0260 72 34 Dimension drawings...

Страница 35: ...FOCH0320 52 Dimension drawings 35...

Страница 36: ...36...

Страница 37: ...by navigating to www abb com contact centers Product training For information on ABB product training navigate to new abb com service training Providing feedback on ABB manuals Your comments on our ma...

Страница 38: ...www abb com drives 3AFE68577519G Copyright 2024 ABB All rights reserved Specifications subject to change without notice 3AFE68577519 Rev G EN 2024 03 12...

Отзывы: