A.6 Safety center response times
Subsystem response times
The following reaction times are estimated for the system. They have to be
considered when calculating stopping distances.
Response times Pluto
•
Program execution time: ~5 ms (~10 µs per instruction, estimated number
of instructions < 500)
•
Static or DynA input to any output: < 20.5 ms + program execution time
•
Bus response time: + 10 ms
Response times external components
•
Response time safety relay (Sentry BSR-series and SSR-series, E1T, RT9):
< 20 ms
•
Light guard (Orion 2 Base): 16 ms
•
Eden DYN / Magne safety switch: < 30 ms
Resulting system stop times
Typical total response times for initiating robot stop motion
•
Protective stop due to light beam violation: < 61.5 ms
(< 16 ms + 20.5 ms + 5 ms + 20 ms)
•
Protective stop due to door opening violation: < 75.5 ms
(< 30 ms + 20.5 ms + 5 ms + 20 ms)
Typical response times for external emergency stop
•
External emergency or protective stop transfer to other equipment: < 45.5 ms
(< 20.5 ms + 5 ms + 20 ms)
Typical response times for internal emergency stop
•
Response time: < 25.5 ms
(< 20.5 ms + 5 ms + 20 ms)
Application manual - FlexLoader Standard Safety Center
61
3HAC051769-001 Revision: E
© Copyright 2014-2020 ABB. All rights reserved.
A Technical data
A.6 Safety center response times
Содержание FlexLoader
Страница 1: ...ROBOTICS Application manual FlexLoader Standard Safety Center ...
Страница 6: ...This page is intentionally left blank ...
Страница 18: ...This page is intentionally left blank ...
Страница 28: ...This page is intentionally left blank ...
Страница 30: ...This page is intentionally left blank ...
Страница 42: ...This page is intentionally left blank ...
Страница 48: ...This page is intentionally left blank ...
Страница 52: ...This page is intentionally left blank ...
Страница 66: ......
Страница 67: ......