Parameterization
OI/FEX300/FEX500-EN FEX300,
FEX500
111
Menu / Parameter
Value range
Description
Communication / Cyclic Data Out /
Cyclic Upd. Select
Flow Group
On / Off
Contents: Q(%), Q(l/s), v(m/s)
Outputs Group
On / Off
Contents: 20mA output
[Io(mA)], frequency at digital
output DO1 [f1(Hz)],
frequency at digital output
DO2 [f2(Hz)]
Status Group
On / Off
Contents: Alarm, Empty Pipe
Frequency [EPD (Hz)], TFE
Frequency [TFE (Hz)]
Coil Group
On / Off
Contents: Coil current
[Ic(mA)], Coil voltage [CV(V)],
Total coil resistance
[CR(Ohm)]
TX Group
Contents:
Reference voltage digits [Ref],
Differential signal at ADC
[SP], SignalMax [SM],
SignalMin [Sm], SignalError
from NR filter [SE], Signal DC
errors [SDE], Internal
amplification [Api], Signal to
noise ratio SNR
Vol. Totals Group
On / Off
Contents:
Forward totalizer [Fwd (m
3
)],
Reverse totalizer [Rev (m
3
)],
Differential totalizer [Net (m
3
)]
Electrodes Group
On / Off
Contents: Electrode
impedance E1 to ground [IE1
(kOhm)], Electrode
impedance E2 to ground [IE2
(kOhm)], Deposit values of
electrode 1 [QE1] and aE1,
Electrode values of electrode
2
[QE2] and aE2, Gas bubble
value [Gasb], Conductivity
[conduS], Sensor temperature
[sensorT°C]
Select the data to be output via the infrared service
port. Diagnostic data is compiled in groups. Each
group can be separately switched on or off, and
thereby added to the diagnostic data record.
italics
= Parameter can only be viewed at the "Advanced" password level.
1) Parameter / menu only available for FEP500 / FEH500.