Safety instructions
WARNING
! Obey the safety instructions of the drive. If you ignore them, injury or death, or
damage to the equipment can occur.
Mechanical installation
Electrical installation
Layout of the module
1.
Pull out the lock.
2.
Install the module carefully to an option
module slot of the drive. See the drive
hardware manual.
3.
Push in the lock.
4.
Tighten the screw to torque 0.8 N·m
using a Torx TX10 screwdriver.
1
3
4
WARNING
! Do not use excessive force, or leave the screw too loose. Over-tightening can
damage the screw or module. A loose screw decreases the EMC performance, and can
cause an operation failure.
No.
Description
1
Lock
2
Mounting and grounding screw
3
RJ-45 connector [X1]
4
RJ-45 connector [X2]
5
Diagnostic LEDs
6
MAC address
5
3
2
4
1
6
—
OPTIONS FOR ABB DRIVES
FEPL-02 Ethernet POWERLINK adapter
module
Quick installation and start-up guide