background image

ABB-Welcome

  |

— 4 —

Pos: 6 /Busc h-Ja ege r (N eust rukt ur)/ Mo dul-St ruktu r/Onli ne-D oku ment ation /Übe rschri ften  (- -> Für alle D okum ent e < --)/ 1. Eb ene/S  - T /Sicher heit @  18\ mod _13 026 127 917 90_ 15.d ocx @  103 357  @ 1  @ 1

1

Information about the manual

Please read this manual through carefully and adhere to the information contained therein.
This will assist you in preventing injury to persons and damage to property and ensure
reliable operation and long service life of the device.

Please keep this manual in a safe place.

If you pass the device on, also include this manual.

Busch-Jaeger accepts no liability for failure to observe the instructions in this manual.

If you require additional information or have questions about the device, please contact
Busch-Jaeger or visit our Internet site at:

www.BUSCH-JAEGER.com

www.abb.com/freeathome

Note...

Detailed information for planning ABB-W elcome systems and ABB-
free@home systems is contained in the system manuals. Download at
www.Busch-Jaeger.com or www.abb.com/freeathome

Pos: 8 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (-->

Für alle Dokumente <--)/1. Ebene/A - F/Bestimmungsgemäßer Gebrauch @

18\mod_1302763321316_15.docx @ 103483 @ 1 @ 1

2

Safety

The device has been constructed according to the latest valid regulations governing
technology and is operationally reliable. It has been tested and left the factory in a
technically safe and reliable state.

However, residual hazards remain. Read and adhere to the safety instructions to prevent
such hazards.

Busch-Jaeger accepts no liability for damages resulting from failure to observe the safety
instructions.

2.1

Used symbols

The following symbols point to dangers involved in the use of the device and
provide practical instructions.

Содержание DP7-S-611

Страница 1: ...eitun gen Online Inh alt KNX Doo rEntry 832 20 AP xxx Tit elblat t 832 20 AP xxx ABB 1 9 m od_ 132 3249 806 476 _15 docx 11 108 4 1 DP7 S 611 DP7 S 625 7 Video hands free indoor station with free home function E nde der Liste für Tex tma rke C over ...

Страница 2: ...on Error Bookmark not defined 4 1 Scope of supply Error Bookmark not defined 4 2 Type overview Error Bookmark not defined 4 3 Function overview free home Error Bookmark not defined 5 Operation 4 5 1 Standard operations 11 5 1 1 Control elements 11 5 1 2 Welcome screen and status bar 13 5 1 3 DES functions in ABB free home system 15 5 1 4 free home 16 5 2 Control actions 17 5 2 1 Surveillance 17 5 ...

Страница 3: ... 53 5 2 12 13 Camera List 55 5 2 12 14 Language 56 5 2 12 15 Setup 57 5 2 12 16 Firmware Update 60 5 3 Cleaning 61 5 4 Adjusting the device 62 5 4 1 Terminal resistor 62 5 4 2 Connection 63 6 Technical data 64 6 1 Main overview 64 6 2 Dimensions 64 7 Mounting Installation 65 7 1 Requirements for the electrician 65 7 2 General installation instructions 66 7 3 Mounting 67 E nde der Liste für Tex tma...

Страница 4: ... Internet site at www BUSCH JAEGER com www abb com freeathome Note Detailed information for planning ABB Welcome systems and ABB free home systems is contained in the system manuals Download at www Busch Jaeger com or www abb com freeathome Pos 8 Busch Jaeger Neustruktur Modul Struktur Online Dokumentation Überschriften Für alle Dokumente 1 Ebene A F Bestimmungsgemäßer Gebrauch 18 mod_130276332131...

Страница 5: ...wing symbols are used in the manual to draw attention to special dangers This symbol indicates a dangerous situation due to electric current If such a sign is ignored it can lead to serious injuries or even death 2 2 Intended use The ABB free homeTouch 7 DP7 S 6xx is an integral part of the ABB Welcome door communication system and operates exclusively with components from this system can be used ...

Страница 6: ...installers must have read and understood the manual and follow the instructions provided The electrical installers must adhere to the valid national regulations in their country governing the installation functional test repair and maintenance of electrical products The electrical installers must be familiar with and correctly apply the Five safety regulations DIN VDE 0105 EN 50110 1 Disconnect fr...

Страница 7: ...on on protection of the environment All packaging materials and devices bear the markings and test seals for proper disposal The products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance EU Directive 2002 96 EG WEEE and 2002 95 EG RoHS EU REACH Directive and Law for the Execution of the Directive EG No 1907 2006 The device conta...

Страница 8: ... pure video indoor station without a connection to the free home system It is not possible to operate the panel without being connected to the Welcome bus This means that at least one ABB Welcome system controller or one additional power supply is to be provided to ensure that the panel is supplied with power Up to 16 free home functions can be positioned on the free home operating page The room t...

Страница 9: ...functions and applications of the device Icon of the operating surface Information Name Floor ringing Type Sensor Made available by free homeTouch 7 Function Signals an incoming floor call Application a free home actuator is to switch during an incoming floor call Name Floor call button Type Actuator Made available by free homeTouch 7 Function Triggers a floor call Application a free home sensor i...

Страница 10: ...in the Allocation area The functions can be positioned on the floor plan and then like any other sensor or actuator connected in the Linking area with other sensors and actuators The Door call function offers 4 linking functions for each of the 4 possible Welcome outdoor stations This allows specific actions to be configured separately for each entrance of the house These are triggered as soon as ...

Страница 11: ... 1 5 1 Standard operations Pos 20 Di nA4 A nleitu ngen Onlin e Ueb ersc hrift en 3 Bedie nele men te 20 mod _13 232 6022 055 9_1 5 do cx 1 116 47 3 1 5 1 1 Control elements Pos 21 Di nA4 A nleitu ngen Onlin e In halt KNX Do orEnt ry 83 220 AP xxx Be dienel eme nte 8 322 0 AP xxx 18 mo d_1 3032 128 536 05_ 15 d ocx 103 673 1 Fig 2 Control elements ...

Страница 12: ...de press this button to mute the ringtone for this indoor station 4B In standby mode hold this button to mute the ringtone for all indoor stations in the apartment 4C While a call is coming press this button to reject the call 4D During the conversation press this button to mute the microphone If the LED lights up this indicates a mute status 5 Programmable button 5A Release the lock connected wit...

Страница 13: ...mber of the indoor station default outdoor station master or slave station on this panel and the current software information 4 History New information is available in History events and picture memory when this icon flashes it means a missed call or a voice message Touch this button to display the events and picture memory 5 Mute function Icons crossed out handset and crossed out bell indicate th...

Страница 14: ...abled during cleaning 10 SOS Press this button for 3s to send an SOS signal to a gurad unit 11 Surveillance Touch this button to start to survey the default outdoor station 12 Intercom Touch this button to enter the intercom call menu 13 Guard unit Touch this button to call a guard unit 14 Switch Actuator Touch this button to enter the switch actuator menu Pos 29 B usch J aeg er Neus truk tur M od...

Страница 15: ...oor button in Indoorstation 2 Corridor light switches the corridor switching contact of the Welcome system controller 3 Floor call button use a free home sensor to activate simulate the floor call for one Indoorstation floor call likes door bell call without intercom activate a free home actuator with switch relay when the floor call was pushed 4 Automatic door opener use a free home sensor to act...

Страница 16: ...ol One step forward and one step backward 3 Blind control Blinds control Moving up down step up down 4 Room thermostat control Air conditioner control Temperature up down mode switch 5 Scene control Morning Evening Sleep Leaving Home Party Cinema Dinner Presence Simulation Pos 22 B usch J aeg er Neus truk tur M odul Strukt ur O nline Doku me ntatio n Steu er mod ule Onlin e Dok ume ntati on Für al...

Страница 17: ...rveillance Touch this button to start to survey the default outdoor station Only the video connection appears first Press button to activate the voice connection No Function 1 Designation of camera 2 Set volume with the Plus minus buttons 3 If several outdoor stations or external cameras are connected Select a camera with the Forward back buttons 4 Touch the button to set the display Saturation of...

Страница 18: ...x 1 121 09 1 Fig 7 Intercom Touch this button to enter the intercom call menu Then the following functions are available Set the intercom call lists in the System setting intercom setting menu first No Functions 1 The name of an intercom 2 The address of an intercom 3 The type of an intercom external or internal means an external intercom from a different apartment means an internal intercom from ...

Страница 19: ...0 AP xxx Tue r o effne n 832 20 AP x xx 20 m od_ 132 326 795 847 9_15 docx 1 121 09 1 Fig 8 Calling Guard unit Touch the Guard unit button to call a guard unit Then the following functions are available No Functions 1 Designation of a guard unit 2 Set volume with the Plus minus buttons Call Guard unit 2 1 ...

Страница 20: ...9 1 Fig 9 Switch Actuator Touch this button to enter the switch actuator menu Then the following functions are available Set actuator lists in the system setting switch actuator menu first No Functions 1 The name of an actuator 2 The address of an actuator 3 Touch this button to activate the selected actuator 4 Touch this button to go back to the START screen Switch Actuator 4 1 2 3 ...

Страница 21: ...n button No Functions 1 Designation of the camera 2 Set the volume with the Plus minus buttons 3 On condition that several outdoor stations or external cameras are connected select the camera with the Forward back buttons 4 Touch the butons to set the display Saturation of the display plus and minus Contrast of the display plus and minus Pos 29 B usch J aeg er Neus truk tur M odul Strukt ur O nlin...

Страница 22: ... o effne n 832 20 AP x xx 20 m od_ 132 326 795 847 9_15 docx 1 121 09 1 Fig 11 Opening the door Press the key button to activate the door opener Then the following function becomes available No Functions 1 The Open door icon is displayed after you press the door opener or activate the function Automatic door opener 1 ...

Страница 23: ...s No Functions 1 No call is pending If you press the Mute function while no call is pending the bell sound of the panel will be deactivated for a certain period If calls come in during this period of time only the video image is displayed Missed calls are displayed in the events and pictures memory 2 A call is pending If you press the button Mute function during a call the microphone of the panel ...

Страница 24: ... Welcome 24 5 2 8 Activating the custom function Pos 31 Di nA4 A nleitu ngen Onlin e In halt KNX Do orEnt ry 83 220 AP xxx Tue r o effne n 832 20 AP x xx 20 m od_ 132 326 795 847 9_15 docx 1 121 09 1 1 2 3 ...

Страница 25: ...st switch actuator list can be assigned for the program button No Functions 1 If the function release 2nd lock is assigned to the program button the Open door icon will be displayed when you press the program button 2 If the function control switch actuator is assigned to the program button the Actuator icon will be displayed when you press the program button 3 If the function make an intercom cal...

Страница 26: ... The panel records all events Press the History button then the last 100 events will be displayed prior events are overwritten No Functions 1 If you have activated the function Auto snapshots activated in the system settings the flashing icon in the status bar signals a newly taken snapshot The symbol stops flashing when you call up the events and pictures memory 2 Voice message Press the flash bu...

Страница 27: ...ABB Welcome 27 1 2 2 3 4 ...

Страница 28: ...rage history During a call you can take a snapshot at any time by pressing the History button even when the Automatic snapshots function is not activated The events and pictures memory history menu has the following functions No Functions 8 5 6 7 ...

Страница 29: ...e to archive can be copied on an inserted SD card SD SDHC 3 Three pictures are made each time when a visitor rings the bell This ensures that an optimum snapshot is taken All recorded pictures are accessed via the details window 4 Only if a call is an intercom call list the list can be added to the blacklist which is used to prevent unwanted calls from other apartment s 5 Display the details windo...

Страница 30: ...rmation Pos 31 Di nA4 A nleitu ngen Onlin e In halt KNX Do orEnt ry 83 220 AP xxx Tue r o effne n 832 20 AP x xx 20 m od_ 132 326 795 847 9_15 docx 1 121 09 1 Fig 16 Information Above items will be shown on the Information menu ...

Страница 31: ... 31 5 2 11 Inserting the SD card Pos 31 Di nA4 A nleitu ngen Onlin e In halt KNX Do orEnt ry 83 220 AP xxx Tue r o effne n 832 20 AP x xx 20 m od_ 132 326 795 847 9_15 docx 1 121 09 1 Fig 17 Inserting the SD card ...

Страница 32: ...t in the menu 3 Program Button Set functions for the program button 4 Leave Home Management Call forward setting Set the target e g other indoor stations or guard units who you want to forward the call from visitors when you are not at home Message leaving If you are not at home you can record and leave a message before leaving home to notify possible visitors and vice versa 5 Voice Message Create...

Страница 33: ... the outdoor stations the doorbell and others Set the volume for the ringtone 9 Auto Unlock Set the automatic unlock time range 10 Display Settings Different display settings 11 Date and Time Different time settings 12 Language Set the local language 13 Set up Other settings e g automatic snapshots 14 Firmware Update 15 Reset the Factory Default ...

Страница 34: ...e hidden functions click on the scroll buttons 2 2 Touch one of the setting areas 3 Touch the button Set 3 The device turns to the selected settings area The individual functions are described in the following chapters The device turns back to the start page when pressing the button Back 4 By tipping on this button you back to the start page 4 1 2 3 ...

Страница 35: ... external intercom each apartment must have a master indoor station means an internal intercom from the same apartment 4 Add Add a new intercom list A total of up to 32 intercom lists can be added 5 Delete Click on this button to delete an existing intercom entry Finally confirm the dialogue box displayed 6 Back Click on this button so you can return to the system settings menu 7 Adjust Click on t...

Страница 36: ...ome 36 Pressing Add or Adjust Fig 21 Intercom The Intercom has the following functions No Functions 1 Click on the name box so you can edit the name 2 Change the call type through the fold down menu 5 4 1 3 2 1 ...

Страница 37: ...om the same apartment 3 Edit the address via the numeric keyboard from 001 to 250 If the call is an internal intercom there is no need to set the target address 4 Touch the OK button to activate the settings 5 Touch the Back button so you can return to the Intercom settings menu without saving the settings ...

Страница 38: ... actuator 2 Address of an actuator 3 Add By touching the button you can add new actuator entry 4 Delete By tipping the button to delete an existing actuator Finally confirm the dialogue box displayed 5 Back By touching the button you return to system settings 6 Adjust By touching the button you can edit the name and address 3 4 1 2 5 6 ...

Страница 39: ...nctions No Functions 1 Click on this edit box to rename the relay actuator 2 Edit the address via the numeric keypad from 001 to 199 3 Click on the OK button to activate the settings 4 Click on the Back button so you can return to the relay actuation settings menu without saving the settings 4 3 1 2 ...

Страница 40: ...nd lock call to the guard unit intercom call enabling the switch actuator 2nd lock means a lock which is connected with an outdoor station NC NO COM Only the existing intercom call list switch actuator list can be assigned to the program button 2 Click on this button to activate the settings 3 Click on this button to return to the system settings menu without saving the settings 3 2 1 ...

Страница 41: ... to activate or deactivate the call forward command Choose the target type through the fold down menu Tick address numeric keyboard to edit the address if a call type comes from an indoor station If the call forward function is activated the auto unlock function will be disabled 2 Message Leaving Tick the checkbox to activate or deactivate the call forward If the messages leaving function is activ...

Страница 42: ...ABB Welcome 42 3 OK Touch this button to activate the settings 4 Back Touch this button to return to the system settings menu without saving the settings 5 Call forward time can be set from 1 to 30s ...

Страница 43: ...r visitors when the message leaving function is activated 2 Date Time The date and time when voice messages are created 3 Record a New Message Touch the button to create a new voice message 4 Save for Absence Message Set a selected voice message as the absence message 5 Delete Message Click on this button to delete an existing voice message Finally confirm the dialogue box displayed 6 Back Touch t...

Страница 44: ...BB Welcome 44 Touch the button to play the voice message Choosing the Record a New Message to create a new voice message Fig 27 Voice Message Choosing Listen to play a voice message Fig 28 Voice Message ...

Страница 45: ...nctions The function only can be set in master indoor station No Functions 1 Tick the checkbox to activate or deactivate the password function 2 Set the password as you wish in 3 8 digits 3 OK Click on this button to activate the settings 4 Back Tick this button to return to the system settings menu Available only with the keypad 4 3 2 1 ...

Страница 46: ... The order of a list 2 Indoor Station Address Set the address of the target indoor station from 001 to 250 3 Add Touch the button to add a new black list A total of up to 32 black lists can be added 4 Delete Touch the button to delete an existing black list Finally confirm the dialogue box displayed 5 Back Touch this button to return to the system settings menu 4 5 1 2 3 ...

Страница 47: ... other doors by clicking on one of the buttons in the list field 3 Bell sound for apartments Select a bell sound for apartments by clicking on one of the buttons in the list field 4 Bell sound for others Select a bell sound for others by clicking on one of the buttons in the list field e g a call from a guard unit or an intercom call from other apartments 5 Bell sound volume Set the volume of the ...

Страница 48: ...Minutes the active range is highlighted with a frame 7 Repeated Tone The ringtone can be set fixed or cycled Touch Feedback Tick the checkbox to activate or deactivate the feedback tone which sounds when the display or the button is touched 8 OK Touch this button to activate the settings 9 Back Touch this button to return to the system settings menu ...

Страница 49: ...ock When auto unlock is activated the functions leave home management and auto snapshot are disabled 2 On Activate or deactivate the time range when the automatic door opener is activated 3 Start Time Set the start time with the Plus minus button when you activate the timer Before adjusting the Hours or Minutes the active range is highlighted with a frame 4 End Time Set the end time with the Plus ...

Страница 50: ... be activated at the period of time everyday If you choose Weekday the function will be activated at the period of time only on weekdays from Monday to Friday 6 OK Touch this button to activate the settings 7 Back Touch this button to return to the system settings menu without saving the settings Pos 32 B usch J aeg er Neus truk tur M odul Strukt ur O nline Doku me ntatio n Steu er mod ule Onlin e...

Страница 51: ...ock If an SD card with suitable pictures is located in the device you can select a screen saver through the fold down menu If several pictures are stored in the SD card they are displayed as a slide show Slide show electronic picture frame Each picture appears for 20 seconds Picture requirements The pictures must be stored in the SD card in the directory DCIM Digital Camera Images on the first lev...

Страница 52: ...ing the settings 7 Calibration If the buttons and the associated graphics of the display are no longer superimposed the monitor must be calibrated Click on the calibration button and then consecutively click on the 5 displayed position crosses Finally confirm the dialogue box displayed The display has been calibrated 8 Screen saver Off After Select the active period for the screen saver via the fo...

Страница 53: ...e format of the displayed date via the fold down menu 3 OK Click on this button to activate the settings 4 Back Click on this button to return to the start page without saving the settings 5 Summer Time Activate or deactivate during summertime by clicking on the checkbox automatic switchover 6 Date Set the date via with Plus minus buttons Before adjusting the Day Month or Year The active area is h...

Страница 54: ...ABB Welcome 54 Set the time with the Plus minus buttons Before adjusting the Hours Minutes or Seconds the active area is highlighted with a frame ...

Страница 55: ...ted to Camera interface is associated with Indoor station here to activate Visual doorbell function When press the level push button the image from the camera connected to Camera interface will display on the Indoor station 5 When the camera is set as visual doorbell this icon will display to show the status only one camera can be set visual doorbell 1 SYSTEM SETTING CAMERALIST Enable the Camreas ...

Страница 56: ...ng functions No Functions 1 Language list field Here the languages available are listed 2 Scroll To display the hidden languages tick the scroll boxes 3 OK Tick this button to activate the settings 4 Back Tick this button to return to the start page without saving the settings 4 3 1 2 ...

Страница 57: ...ABB Welcome 57 5 2 12 15 Setup Fig 37 Setup 7 6 1 2 3 5 Indoor Staiton Address Door Status Check Automatic Snapshots Home Automation Key Illumination 4 8 ...

Страница 58: ...Automation This option is enabled to use the function of free home 4 Key Illumination Tick the checkbox to activate or deactivate the key illumination If activating the function the key will be illuminated during operation Or else the key illumination will be off all the time 5 Indoor Station Address This option is enabled only when the last two rotary switches of IS are set as 00 and it can be se...

Страница 59: ...functions In the panel configuration the buttons of the ABBfree homeTouch 7 can be freely equipped All panels in the system and the favourites bar can be selected from the bottom selection bar Important Only panels appear that have been previously positioned on the floor plan under commissioning step Allocation The allocated actuator channels can be positioned on the panel via drag and drop from t...

Страница 60: ...able on the Internet at www buschjaeger com If the firmware for your device is to be updated carry out the following steps 1 On page www busch jaeger com enter the article number of the device in the Search section The page changes to the area of the device If an update for the firmware is available it is ready for downloading in this area The package for downloading includes the firmware and inst...

Страница 61: ... Never use such objects for entries on the touch screen monitor Use your finger or a plastic stylus The screen surface can be damaged by cleaning fluids or abrasive agents Clean the surfaces using a soft cloth and commercially available glass cleaner Never use abrasive cleaning agents Pos 69 B usch J aeg er Neus truk tur M odul Strukt ur O nline Doku me ntatio n Steu er mod ule Onlin e Dok ume nta...

Страница 62: ... e In halt KNX Do orEnt ry Bedie nun g M aste r Slave Sc halte r setz en 832 20 AP xxx 1 9 m od_1 310 723 320 966 _15 docx 10 783 3 No Functions 1 Station Selector switch to set the address of default outdoor station 2 X10 X1 Selector switches to set the address tens and units digits of the indoor station Setting hundreds digits need to enter system menu 3 Master Slave function Only one indoor sta...

Страница 63: ...ystem controller When using several indoor stations connection for the internal bus 3 Connection for free home system Pos 75 B usch J aeg er Neus truk tur M odul Strukt ur O nline Doku me ntatio n Steu er mod ule Onlin e Dok ume ntati on Für alle Dok ume nte S eiten umb ruch 9 m od_ 126 8898 668 093 _0 docx 521 49 1 3 ...

Страница 64: ...Value Display resolution 800 x 480 Display size 17 8 cm 7 Operating temperature 10 C 55 C Storage temperature 40 C 70 C Protection IP 30 Single wire clamps 2 x 0 28 mm 2 x 0 75 mm Fine wire clamps 2 x 0 28 mm 2 x 0 75 mm Bus voltage 20 30 V Size 155 mm x 218 mm x 29 mm 6 2 Dimensions Note All dimensions are specified in mm Fig 40 Dimensions Pos 78 B usch J aeg er Neus truk tur M odul Strukt ur O n...

Страница 65: ...V supply system to be performed by specialist staff Pos 81 B usch J aeg er Neus truk tur M odul Strukt ur O nline Doku me ntatio n Siche rheit Fü r alle D oku ment e War nhinweis e Siche rheit Fachk enn tnisse 18 mo d_1 302 774 384 017_ 15 docx 10 356 4 2 1 7 1 Requirements for the electrician Warning Electric voltage Install the device only if you have the necessary electrical engineering knowled...

Страница 66: ...system controller directly next to the bell transformer and other power supplies to avoid interference Do not install the wires of the system bus together with 100 240 V wires Do not use common cables for the connecting wires of the door openers and wires of the system bus Avoid bridges between different cable types Use only two wires for the system bus in a four core or multi core cable When loop...

Страница 67: ... DinA4 Anleit ung en O nline I nhal t KNX DoorE ntry 832 20 AP xxx Mo nta ge Mo dule Mon tag e Mon tage dos e 83 220 AP xxx 19 mod _132 325 040 684 8_1 5 doc x 1 110 98 1 Dismantling Open the housing of the panel by pulling the clamp at the bottom of the device Mounted on the wall or flush mounted box Fix the bottom of the device directly on a level wall surface or on an flush mounted socket accor...

Страница 68: ...on on the rotary switches Set the master slave function and the terminal resistor on the switches at the rear of the top part of the housing see chapter Terminal Resistor Latch the device Latch the upper part of the device onto its bottom part place the upper side of the device on the lock in lugs and then press the bottom side onto the bottom part of the device until it is caught by the clamp ...

Страница 69: ...p bracket 2 Latch the upper part of the device onto its bottom part To do this place the upper side of the device on the lock in lugs and then press the bottom side onto the bottom part of the device until the it is caught by the clamp The installation of the indoor station is now complete ...

Страница 70: ... Ba ckcove r We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained there...

Отзывы: