Pulling out the cable package
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx2000001564
Remove the axis-1 connector plate.
2
Wrap the connectors with the masking tape.
3
xx2000001563
Pull out the cable package in the direction as
shown in the figure.
Note
Slip out the cable protectors while pulling out the
cable package.
4
Slip out the cable protectors.
5
Refitting the cable package
Use these procedures to refit the cable package.
Securing the cable package in the base
Note
Action
Wrap the connectors with the masking tape.
1
Continues on next page