ALL RELEVANT FIRE REGULATION MUST BE
STRICTLY OBSERVED.

WARNING

TRANSFORMER COMPONENTS

Electronic Liquid level  indicator eOLI/eOLI22 and Comem
eViewer

Quick start

1.

Safety

1.1  

Safety instruction

Make sure that any personnel installing:
•  are technically qualified and competent
•  fully comply with these assembling
instructions
Improper operations or misuse could cause
danger to:
•  life and limb
•  to the equipment and other assets of the
operator
•  to the proper function of the equipment
Safety instructions in this manual are shown in
three different forms to emphasize important
information

1.2 

 Specified applications

The liquid level indicator is used in oil-insulated
transformer to indicate the conservator tank oil
level. Inside the device are usually installed up to
four micro-switches to signal some critical oil
levels. The micro-switches can give alarm or
transformer power off signals

It is important to observe the limit values
indicated on the nameplate and in the operating
instruction before commissioning the device

1.3  

Safety notes on the equipment

operation
Electrical installation is subject to the relevant
national safety rules.
It is mandatory to connect the grounding cable

THIS INFORMATION INDICATES PARTICULAR
DANGER TO EQUIPMENT AND/OR OTHER
PROPERTY OF THE USER. SERIOUS OR FATAL

INJURY CANNOT BE EXCLUDED.

CAUTION

THIS INFORMATION INDICATES PARTICULAR DANGER TO
LIFE AND HEALTH. DISREGARDING SUCH A WARNING
CAN LEAD TO SERIOUS OR FATAL INJURY.

WARNING

THIS NOTE GIVES IMPORTANT AND SPECIFIC
INFORMATION CONCERNING THE EQUIPMENT.

NOTE

INSTALLATION, ELECTRICAL CONNECTION AND FITTING
THE DEVICE MAY ONLY BE PERFORMED BY QUALIFIED
PERSONNEL AND ONLY IN ACCORDANCE WITH THIS
INSTRUCTION MANUAL. IT IS THE RESPONSIBILITY OF
THE USER TO ENSURE THAT THE DEVICE IS USED FOR
SPECIFIED APPLICATION ONLY.

FOR SAFETY REASONS, PLEASE AVOID ANY
UNAUTHORIZED AND IMPROPER USAGE.

ALL RELEVANT FIRE PROTECTION REGULATIONS
MUST BE STRICTLY FOLLOWED

CAUTION

Содержание Comem eOLI22

Страница 1: ...transformer power off signals It is important to observe the limit values indicated on the nameplate and in the operating instruction before commissioning the device 1 3 Safety notes on the equipment operation Electrical installation is subject to the relevant national safety rules It is mandatory to connect the grounding cable THISINFORMATIONINDICATESPARTICULAR DANGERTOEQUIPMENTAND OROTHER PROPER...

Страница 2: ...NOTE FOR COMEM eOLI eOLI22 The electrical micro switches operate at an advance angle 5 with respect to the min or max indications of the oil level in the conservator When there is a double contact for e g double MIN and or double MAX schemes Y o W the second contact operates at about 5 after the first contact NOTE ...

Страница 3: ...ole on the conservator Place the o ring in the slot behind the flange Fig 1 C Insert the flange on the threaded pins Fig 1 A of the conservator flange and fix it with the items showed in the table 2 Fig 1 B Fix the gauge on the flange using 4 screws M4x12 Fig 1 D 3 3 Comem eViewer Arrange the transformer with a dedicated place following the scheme in the figure 3 The connection can be done in two ...

Страница 4: ...ion 20 mA 100 maximum arrow position 4 2 3 Modbus communication Digital output RS485 terminals 3 4 for the Modbus register and address check the complete manual instruction Manual instruction 4 3 Comem eViewer wiring 4 3 1 Power voltage Connect the power voltage as written inside the terminal box Fig 5 to terminals 1 2 24 Vdc 10 4 3 2 Analog input Connect the analog signal as written inside the te...

Страница 5: ...us output on eOLI eOLI22 If the eDevice is properly powered on see below row check the Modbus ID and register number Pointer on the dial is always at the lowest position Check that the floating element is not damaged eViewer does not indicate any value even if it is connected to the eOLI eOLI22 Check the polarity connection of the 4 20mA terminals For further information check the complete manual ...

Отзывы: