Installation
Probe tube and filter unit installation
CAUTION
Injury hazard due to heavy weight
The weight of the probe tube with filter unit amounts to approx. 18 to 20 kg!
• Two persons are required for transportation and mounting!
Before the installation
• Observe the ‘Piping plan’ in the drawings set.
• Make sure that the wall tube is installed at the extraction point, see .
Filter unit overview
A
Sample gas inlet
B
Sample gas outlet
C
Backpurging air inlet from solenoid valve S0V2
D
Backpurging air inlet from solenoid valve S0V1
1
Flange
2
Internal thread connection for probe tube
3
Filter element
4
Housing with thermal Insulation
5
Cover with thermal insulation
6
Heater element
7
Filter housing
8
T-handle
9
Terminal box for heater power supply and status contact
0
Cable glands
Figure 11: Filter unit