Configuration • Software • OPC UA server
108
Power Panel FT50 User's manual V1.19
7.3.4.2.3 Control
Path to the object directory:
Path:
0:Root/0:Objects/2:DeviceSet/4:PowerPanelFT50/3:Control
ns BrowseName of the method
Description
"Wakes up" the Power Panel when the screensaver is running.
Plays the buzzer with the system settings.
Plays the buzzer with the specified parameters.
The Power Panel loads the last saved settings and restarts. Any changes made to the
are not saved
and are lost.
Saves changes made to the
. Method
must be used to enable these stored settings
on the Power Panel.
Changes the screen brightness in the range 20% to 100%.
Changes the screen brightness in the range 0% to 100%.
Sets the date and/or time of the device.
4
Reboots the Power Panel and starts the update process.
7.3.4.2.3.1 AwakePanel
"Wakes up" the Power Panel when the screensaver is running.
Path to the node (BrowsePath)
Path:
0:Root/0:Objects/2:DeviceSet/4:PowerPanelFT50/2:MethodSet/4:AwakePanel
Alternative path (function group):
0:Root/0:Objects/2:DeviceSet/4:PowerPanelFT50/3:Control/4:AwakePanel
Arguments for method call
Arguments
-
7.3.4.2.3.2 BuzzerDefault
Plays the buzzer with the system settings.
Path to the node (BrowsePath)
Path:
0:Root/0:Objects/2:DeviceSet/4:PowerPanelFT50/2:MethodSet/4:BuzzerDefault
Alternative path (function group):
0:Root/0:Objects/2:DeviceSet/4:PowerPanelFT50/3:Control/4:BuzzerDefault
Arguments for method call
Arguments
-
7.3.4.2.3.3 BuzzerWithPara
Plays the buzzer with the specified parameters. See arguments for the method call.
Path to the node (BrowsePath)
Path:
0:Root/0:Objects/2:DeviceSet/4:PowerPanelFT50/2:MethodSet/4:BuzzerWithPara
Alternative path (function group):
0:Root/0:Objects/2:DeviceSet/4:PowerPanelFT50/3:Control/4:BuzzerWithPara
Arguments for method call
Argument
Data type
Name
Description
0
UInt32
Frequency
Frequency of the buzzer in hertz [Hz].
1
UInt32
Duration
Duration of the buzzer in milliseconds [ms].