
AQUA M A STE R4
| EL EC T R O M AG N E T I C FLO W M E T ER T R A N SM I T T ER | O I/FE T4 0 0 - EN R E V. D
45
Data transmission via cellular 4G (FEX45X)
Additional transmitter configuration is required before normal
operation.
Note
:
Below are the additional configurations to be done for normal
operation along with those as per
1
Enable
Advanced Access Level Enable
in
User Access Right
Settings
and navigate to
Advanced Settings – Cellular 4G >
Operation mode
.
2
Click the edit icon and select
Disabled
and tap the phone/
tablet to the device to disable Cellular 4G communication.
3
Configure the below parameters for FTPS server through
Velox interface app under
Advance Settings – Cellular 4G
and tap the phone/tablet to the device to update the
parameters.
Item
Description
Data report time base
e.g. 0 (to set the base time for
sending report at 00:00 h), the
value should be in seconds.
Data report interval
1 hour / 6 hour / 12 hour / 1 day
Data report mode
Detail report / summary report
Alarm report on raise condition
Off / On
Alarm report on clear condition
Off / On
4
In case of Detail report,
Logging interval & Retrieved record
interval
needs to configure under
Process Logger Settings
.
5
Transmitter supports optional SIM card configurations in
Advance Settings – Cellular 4G
.
• SIM card pin: The transmitter supports to set PIN for un-
authorized access by setting the PIN in
Advance Settings –
Cellular 4G > SIM card pin .
• Lock SIM card: Select
On
in
Advance Settings – Cellular 4G
> Lock SIM card
to lock the SIM card with the PIN as per
above.
• Unlock SIM Card: Select
On
in
Advance Settings – Cellular
4G > Unlock SIM card
to unlock the SIM card with the PIN as
per above.
• SIM card PUK: If the PIN is lost, the transmitter allow
customer to enter PUK (Personal Unblocking Key) for the
SIM card with the reset PIN code under
Advance Settings –
Cellular 4G > SIM card puk
.
6
Navigate to
Advanced Settings – Cellular 4G > Operation
mode
.
7
Click the edit icon and select
Enabled
and hover the phone/
tablet to the transmitter to enable Cellular 4G
communication.
8
Reboot the transmitter through Velox by selecting
On
in
Firmware Information > Reboot system
and hover the
phone/tablet to device and the transmitter is now ready for
normal operation.
Note
:
Renewal for SSL/TLS keys and certificates is easy and similar to
the steps as per page 38. Every time when a new signed CSR file
is exported, the internal 4G private key will be renewed meaning
the previous internal 4G private key is erased and cannot be
used. The renewed and signed device public-key certificate
should be imported into the device to make sure that the
interval 4G private key and the device public-key certificate are
used in pair. Similarly, importing the trust anchor will renew the
trust anchor with the previous one.