1.0 Information

Tab

2.0 Measurements

AquaMaster

12:31:00

ABB Automation

25/12/1998

Stonehouse

Test Mode

Flow

etc.

Pressure

  

Esc

Flow Units

l/s

Flow Units?

l/s

Flow Units?

l/m

Flow Units

: l/m

FSD(100% or URV) 200 l/m

Tab

Space

Space

(Repeat space function
key until required units
are displayed)

>217

 

<0>217=42

>217=42

<3>217=Write Access Denied

Comments

 

 >248=setup

<0>248=2 logged in

enter password

  >112

   

                   

<0>112=1 l/s

read present flow units

  >115

  

                    

<0>115=250

read present fsd

  >115=10

  

                

<0>115=10

set new fsd value of 10

  >112=6

  

                 

<0>112=6 m^3/m

set units to number 6 (m^3/min)

Function Key

4.0 Access

Language

:English

Login (Password?)

:Log In Level 0   

Space

Login (Password?)?

Login (Password?)

:2 Level Logged In

4.0 Access

5.0 Flow Settings

6.0 Pressure Settings

         etc.

Esc

Tab

Tab

Tab

Tab

setup

88888.888.

8

gal

m

3

AB

.8.8.8.80

f t m

3 / h M G D

g a l / s m B a r p s i

0

-

 Pictorial Displays

Left Battery Warning

Sensor Fault

Empty Pipe

Mains Failure

Right Battery Warning

Lower Display

Time
Flow Velocity
Pressure

Upper Display

Date
Forward Flow Total
Reverse Flow Total
Net Flow Total
Tariff Totals

Tariff Indicator

Quick Reference Guide

Electronic

Commercial

Water Meters

with

Integral Logger

AquaMaster S

IM/AMS/QRG

Issue 5 08.04

DISPLAY

PROGRAMMING

…PROGRAMMING

SECURITY ACCESS

PARAMETER CHANGES

ABB Limited

Oldends Lane, Stonehouse, Gloucestershire, GL10 3TA, UK
Tel: +44 (0)1453 826661,  Fax: +44 (0)1453 829671

When the unit is taken out of storage and installed for
first use, remove the protective label, if fitted, from the
front, to allow light to activate the unit.

If the instrument is not powered, connect any batteries
or external supply as detailed in the Installation Manual.

Important.

 Read the manual for battery condition

monitoring.

Setting up the PC – HyperTerminal Setup

(Example from Windows NT – other Windows vary)
From the PC 

Start 

menu choose 

Programs –

Accessories – Hyperterminal – HyperTerminal

.

At 'New connection' enter : AquaMaster
At 'Connect using' choose : COM1 or COM2 depending

on the pc connection

At 'Port setting' prompt choose Bits per second: 4800,
Data bits: 8, Parity: None, Stop bits: 1, Flow control:
none.

Programming the AquaMaster

To access programming mode, connect the
AquaMaster to a computer via either of the serial port
connections – see Instruction Manual ('Local or Remote
Computer Connection' sections).
Use serial port settings: 4800 Baud, 8 data bits,1 stop
bit and no parity.
Press 

Tab

 twice to activate the programming mode.

The following display appears on the computer screen:

AquaMaster…
Nav Mode: TAB, Disp Mode: Ctrl + W

Pressing the 

Ctrl

 + 

W

 keys simultaneously

produces the display mode, with the same information
as that on the transmitter display.

Press 

Esc

 to cancel display mode.

Pressing the 

Tab

 key produces the following screen:

[Next Menu=TAB][Next Item=ENTER]
[Edit = SPACE][Exit = Esc]
1.0 Information

Further key operations access the menus as follows:

Key

= Menu Displayed Text; = User entered data  ; =

Note. 

Pressing 

M

 within a menu will list all the

remaining parameters immediately.

There are two levels of password control:

Level Default Password Menus

2

setup

1 to 7

4

am2k

1 to 11

      

Note.

 Passwords are case sensitive

Logging In

Note

. Use 

Esc

 to escape or cancel in input mode, or to

exit a menu.

Changing Selections

Note

. Ensure that the correct access level is selected.

It is possible to enter data directly into the AquaMaster
without navigating the menu system. This is achieved by
using the "Command Line Interface" (CLI). To read the value of
a variable, type a right chevron 

>

 followed by the variable

number (see overleaf), then press 

.

To write a new value to a variable, type a right chevron 

>

,

the variable number, an equal sign 

=

 and the new value

required, followed by 

. In both cases the AquaMaster will

reply with the new value of the variable (or a reason for failure)
e.g.:

Where

217

is the number for the flow rate

<0>

is the error code for “no error”

42

is the current flow rate

<3>

is the error code for “Write Access Denied”,
since writing to the flow rate is not allowed.

To change the flow FSD to 10 m

3

/min:

To cancel the password security, press 

Esc

 until the front

screen is reached.

Display