Standard function blocks
371
Extensions
FIO_01_slot1
(10084)
Illustration
Execution time
8.6 µs
Operation
The block controls the four digital inputs/outputs (DIO1…DIO4) and two relay outputs
(RO1, RO2) of a FIO-01 Digital I/O Extension mounted on slot 1 of the drive control unit.
The state of a DIOx conf input of the block determines whether the corresponding DIO
on the FIO-01 is an input or an output (0 = input, 1 = output). If the DIO is an output, the
DOx input of the block defines its state.
The RO1 and RO2 inputs define the state of the relay outputs of the FIO-01 (0 = not
energised, 1 = energised).
The DIx outputs show the state of the DIOs.
Inputs
Digital input/output mode selection (DIO1 conf … DIO4 conf): Boolean
Digital output state selection (DO1…DO4): Boolean
Relay output state selection (RO1, RO2): Boolean
Outputs
Digital input/output state (DI1…DI4): Boolean
Error output (Error): DINT (0 = No error; 1 = Application program memory full)
FIO_01_slot1
49
TLA1 1 msec
(1)
DIO1 conf
DIO2 conf
DIO3 conf
DIO4 conf
DO1
DO2
DO3
DO4
RO1
RO2
DI1
DI1(49)
DI2
DI2(49)
DI3
DI3(49)
DI4
DI4(49)
Error
Error(49)
Содержание ACSM1 Series
Страница 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Страница 4: ......
Страница 34: ...Drive programming using PC tools 34 ...
Страница 86: ...Drive control and features 86 ...
Страница 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Страница 302: ...Parameter data 302 ...
Страница 422: ...Application program template 422 ...
Страница 430: ...Appendix A Fieldbus control 430 ...
Страница 500: ...Appendix D Application examples 500 ...
Страница 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Страница 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...