Drive control and features
36
Local control is mainly used during commissioning and maintenance. The control
panel always overrides the external control signal sources when used in local
control. Changing the control location to local can be disabled by parameter
.
The user can select by a parameter (
) how the drive
reacts to a control panel or PC tool communication break.
External control
When the drive is in external control, control commands (start/stop, reset etc.) are
given through the fieldbus interface (via an optional fieldbus adapter module), the I/O
terminals (digital inputs), optional I/O extension modules or the drive-to-drive link.
Two external control locations, EXT1 and EXT2, are available. The user can select
control signals (eg,
) and control modes (
) for both external control locations. Depending on the user selection, either
EXT1 or EXT2 is active at a time. Selection between EXT1/EXT2 is done via a freely
selectable bit pointer parameter
. In addition, the EXT1
control location is divided into two parts, EXT1 CTRL MODE1 and EXT1 CTRL
MODE2. Both use the EXT1 control signals for start/stop, but the control mode can
be different; for example, EXT1 CTRL MODE2 can be used in homing.
Operating modes of the drive
The drive can operate in speed and torque control modes as well as position,
synchron, homing and profile velocity modes. Block diagrams of the control chain for
speed and torque control as well as positioning are presented on page
; more
detailed diagrams are presented in
Appendix E – Control chain and drive logic
(page
).
Speed control mode
Motor rotates at a speed proportional to the speed reference given to the drive. This
mode can be used either with estimated speed used as feedback, or with an
encoder or resolver for better speed accuracy.
Speed control mode is available in both local and external control.
Torque control mode
Motor torque is proportional to the torque reference given to the drive. This mode
can be used either with estimated speed used as feedback, or with an encoder or
resolver for more accurate and dynamic motor control.
Torque control mode is available in both local and external control.
Содержание ACSM1 Series
Страница 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Страница 4: ......
Страница 34: ...Drive programming using PC tools 34 ...
Страница 86: ...Drive control and features 86 ...
Страница 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Страница 302: ...Parameter data 302 ...
Страница 422: ...Application program template 422 ...
Страница 430: ...Appendix A Fieldbus control 430 ...
Страница 500: ...Appendix D Application examples 500 ...
Страница 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Страница 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...