Drive programming using PC tools
32
Program execution
The application program is loaded to the permanent (non-volatile) memory of the
memory unit (JMU). When the loading finishes, the drive control board is
automatically reset, and the downloaded program started. The program is executed
in real time on the same Central Processing Unit (CPU of the drive control board) as
the drive firmware. The program can be executed at the two dedicated time levels of
1 and 10 milliseconds, as well as other time levels between certain firmware tasks.
Note:
Because the firmware and application programs use the same CPU, the
programmer must ensure that the drive CPU is not overloaded. See parameter
.
Application program licensing and protection
Note:
This functionality is only available with DriveSPC version 1.5 and later.
The drive can be assigned an application licence consisting of an ID and password
using the DriveSPC tool. Likewise, the application program created in DriveSPC can
be protected by an ID and password. For instructions, refer to the DriveSPC user
manual.
If a protected application program is downloaded to a licensed drive, the IDs and
passwords of the application and drive must match. A protected application cannot
be downloaded to an unlicensed drive. On the other hand, an unprotected
application can be downloaded to a licensed drive.
The ID of the application licence is displayed by DriveStudio in the drive software
properties as APPL LICENCE. If the value is 0, no licence has been assigned to the
drive.
The parameters that are created using the DriveSPC parameter manager with hide
flags can be viewed or hidden by parameter
. The password code
must be the same as the drive APPL LICENCE. A wrong password code will hide the
visible application parameters again.
Notes:
• The application licence can only be assigned to a complete drive, not a stand-
alone control unit.
• A protected application can only be downloaded to a complete drive, not a stand-
alone control unit.
Содержание ACSM1 Series
Страница 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Страница 4: ......
Страница 34: ...Drive programming using PC tools 34 ...
Страница 86: ...Drive control and features 86 ...
Страница 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Страница 302: ...Parameter data 302 ...
Страница 422: ...Application program template 422 ...
Страница 430: ...Appendix A Fieldbus control 430 ...
Страница 500: ...Appendix D Application examples 500 ...
Страница 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Страница 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...