Maintenance
69
Reforming the capacitors
The capacitors must be reformed if the drive has been stored for a year or more. See
page
for information on finding out the manufacturing date. For information on
reforming the capacitors, contact your local ABB representative.
Other maintenance actions
Transferring the memory unit to a new drive module
When a drive module is replaced, the parameter settings can be retained by
transferring the memory unit from the defective drive module to the new module.
WARNING!
Do not remove or insert a memory unit when the drive module is
powered.
After power-up, the drive will scan the memory unit. If a different application program
or different parameter settings are detected, they are copied to the drive. This may
take a few moments; the LED display will read “L” while copying is in progress.
The 7-segment display on the JCU Control Unit
The following table describes the indications given by the 7-segment display on the
JCU Control Unit. Multi-character indications are displayed as repeated sequences
of characters.
Display
Meaning
L
Loading application program or data from the memory unit. This is the normal
display immediately after powering up the drive.
Normal operation – drive stopped.
(Rotating display) Normal operation – drive running.
“E” followed by
four-digit error code
System error.
9001, 9002 = Control unit hardware failure.
9003 = No memory unit connected.
9004 = Memory unit failure.
9007, 9008 = Loading of firmware from memory unit failed.
9009…9018 = Internal error.
9019 = Contents of memory unit corrupted.
9020 = Internal error.
9021 = Program versions of memory unit and drive incompatible.
9102…9108 = Internal error.
“A” followed by
four-digit error code
Alarm generated by the application program. For error codes, see the Firmware
Manual.
“F” followed by
four-digit error code
Fault generated by the application program. For error codes, see the Firmware
Manual.
Содержание ACSM1 Series
Страница 1: ...ACSM1 Hardware Manual ACSM1 04 Drive Modules 0 75 to 45 kW...
Страница 2: ......
Страница 4: ......
Страница 14: ...Table of contents 14...
Страница 20: ...About this manual 20...
Страница 24: ...The ACSM1 04 24...
Страница 30: ...Planning the cabinet assembly 30...
Страница 46: ...Planning the electrical installation 46...
Страница 70: ...Maintenance 70...
Страница 84: ...Technical data 84...
Страница 90: ...Mains filters 90...
Страница 96: ...Dimension drawings 96 Frame size A...
Страница 97: ...Dimension drawings 97...
Страница 98: ...Dimension drawings 98 Frame size B...
Страница 99: ...Dimension drawings 99...
Страница 100: ...Dimension drawings 100 Frame size C air cooled module...
Страница 101: ...Dimension drawings 101...
Страница 102: ...Dimension drawings 102 Frame size C for cold plate mounting...
Страница 103: ...Dimension drawings 103 Frame size D air cooled module...
Страница 104: ...Dimension drawings 104 Frame size D for cold plate mounting...
Страница 106: ...Dimension drawings 106 Mains filters type JFI xx...
Страница 108: ...Dimension drawings 108 Braking resistors type JBR xx...
Страница 110: ...Dimension drawings 110...
Страница 111: ......