97.07
LQ USER
FW block: None
Defines the quadrature axis (synchronous) inductance.
Note:
This parameter is valid only for permanent magnet motors.
0…10 p.u. (per unit)
Quadrature axis (synchronous) inductance.
97.08
PM FLUX USER
FW block: None
Defines the permanent magnet flux.
Note:
This parameter is valid only for permanent magnet motors.
0…2 p.u. (per unit)
Permanent magnet flux.
97.09
RS USER SI
FW block: None
Defines the stator resistance
R
S
of the motor model.
0.00000…100.00000 ohm
Stator resistance.
97.10
RR USER SI
FW block: None
Defines the rotor resistance
R
R
of the motor model.
Note:
This parameter is valid only for asynchronous motors.
0.00000…100.00000 ohm
Rotor resistance.
97.11
LM USER SI
FW block: None
Defines the main inductance
L
M
of the motor model.
Note:
This parameter is valid only for asynchronous motors.
0.00…100000.00 mH
Main inductance.
97.12
SIGL USER SI
FW block: None
Defines the leakage inductance
σ
L
S
.
Note:
This parameter is valid only for asynchronous motors.
0.00…100000.00 mH
Leakage inductance.
97.13
LD USER SI
FW block: None
Defines the direct axis (synchronous) inductance.
Note:
This parameter is valid only for permanent magnet motors.
0.00…100000.00 mH
Direct axis (synchronous) inductance.
97.14
LQ USER SI
FW block: None
Defines the quadrature axis (synchronous) inductance.
Note:
This parameter is valid only for permanent magnet motors.
0.00…100000.00 mH
Quadrature axis (synchronous) inductance.
Содержание ACSM1 Series
Страница 1: ...ACSM1 Firmware Manual ACSM1 Speed and Torque Control Program...
Страница 2: ......
Страница 4: ......
Страница 12: ...Table of contents 12...
Страница 49: ...Drive control and features 49...
Страница 282: ...Standard function blocks 282...
Страница 306: ...Application program template 306...
Страница 312: ...Control chain block diagrams 312...
Страница 331: ...331...
Страница 332: ...332...
Страница 333: ......