What to do
Cause
Event name /
Aux. code
Code
(hex)
Check the auxiliary code. Add 2 to the
code to find out the node address of
the faulted drive.
A follower drive has tripped.
Follower
FF7E
Correct the fault in the follower drive.
Check the fault information provided
by the PLC.
A fault trip command has been
received through fieldbus adapter A.
FB A force trip
FF81
Check the fault information provided
by the PLC.
A fault trip command has been
received through fieldbus adapter B.
FB B force trip
FF82
Check the fault information provided
by the Modbus controller.
A fault trip command has been
received through the embedded
fieldbus interface.
EFB force trip
FF8E
596 Fault tracing