Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
3
This setting is to be used by ABB-authorized service
personnel only.
Custom
Disabled / uint16
Enables signal injection. A high-frequency alternating
signal is injected into the motor at low speeds to
improve the stability of torque control. Signal injection
can be enabled with different amplitude levels.
Note: This is an expert level parameter and should not
be adjusted without appropriate skill.
Note: Use as low a level as possible that gives
satisfactory performance.
Note: Signal injection cannot be applied to
asynchronous motors.
Signal injection
97.10
0
Signal injection disabled.
Disabled
1
Signal injection enabled with an amplitude level of 5%.
Enabled (5 %)
2
Signal injection enabled with an amplitude level of 10%.
Enabled (10 %)
3
Signal injection enabled with an amplitude level of 15%.
Enabled (15 %)
4
Signal injection enabled with an amplitude level of 20%.
Enabled (20 %)
100 % / real32
Rotor time constant tuning.
This parameter can be used to improve torque accuracy
in closed-loop control of an induction motor. Normally,
the motor identification run provides sufficient torque
accuracy, but manual fine-tuning can be applied in
exceptionally demanding applications to achieve
optimal performance.
Note: This is an expert level parameter and should not
be adjusted without appropriate skill.
TR tuning
97.11
1 = 1 % / 100 = 1 %
Rotor time constant tuning.
25...400 %
Parameters 529
Содержание ACS880 N5700 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 32: ...32 ...
Страница 60: ...60 ...
Страница 456: ...Def Type FbEq 16b 32b Description Name Range Selection No 100 1 1 1 Overriding value 0 001 100 000 456 Parameters ...
Страница 546: ...546 ...
Страница 604: ...604 ...
Страница 626: ...626 ...
Страница 640: ...640 ...
Страница 660: ...660 ...