Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
- / -
Number of inverter modules available.
0...65535
- / uint16
(Only visible with a BCU control unit)
Shows which of the parallel-connected inverter modules
have been detected by the control program.
Note: This parameter is read-only.
Connected modules
95.14
Module 1 has been detected.
b0
Module 2 has been detected.
b1
Module 3 has been detected.
b2
Module 4 has been detected.
b3
Module 5 has been detected.
b4
Module 6 has been detected.
b5
Module 7 has been detected.
b6
Module 8 has been detected.
b7
Module 9 has been detected.
b8
Module 10 has been detected.
b9
Module 11 has been detected.
b10
Module 12 has been detected.
b11
Reserved
b12…15
1 = 1
0000h…FFFFh
- / uint16
Contains hardware-related settings that can be enabled
and disabled by toggling the specific bits.
Note: The installation of the hardware specified by this
parameter may require derating of drive output, or
impose other limitations. Refer to the hardware manual
of the drive.
Note: This parameter cannot be changed while the
drive is running.
Special HW settings
95.15
1 = The driven motor is an Ex motor provided by ABB
for potentially explosive atmospheres. This sets the
required minimum switching frequency for ABB Ex
motors.
Note: For non-ABB Ex motors, contact your local ABB
representative.
EX motor
b0
1 = An ABB sine filter is connected to the output of the
drive/inverter.
ABB sine filter
b1
1 = Minimum switching frequency limit adaptation to
output frequency active. This setting improves control
performance at high output frequencies (typically
above 120 Hz.
High speed mode
b2
1 = A custom sine filter is connected to the output of
the drive/inverter. See also parameters
,
,
,
Custom sine filter
b3
Parameters 511
Содержание ACS880 N5700 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 32: ...32 ...
Страница 60: ...60 ...
Страница 456: ...Def Type FbEq 16b 32b Description Name Range Selection No 100 1 1 1 Overriding value 0 001 100 000 456 Parameters ...
Страница 546: ...546 ...
Страница 604: ...604 ...
Страница 626: ...626 ...
Страница 640: ...640 ...
Страница 660: ...660 ...