Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
0.100 s / real32
Defines the filtering time constant for analog output
AO1.
%
100
63
Filtered signal
Unfiltered signal
T
t
O = I × (1 - e
-
t
/T
)
I = filter input (step)
O = filter output
t = time
T = filter time constant
AO1 filter time
13.16
1000 = 1 s / 1000 = 1
s
Filter time constant.
0.000 ... 30.000 s
Parameters 193
Содержание ACS880 N5700 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 32: ...32 ...
Страница 60: ...60 ...
Страница 456: ...Def Type FbEq 16b 32b Description Name Range Selection No 100 1 1 1 Overriding value 0 001 100 000 456 Parameters ...
Страница 546: ...546 ...
Страница 604: ...604 ...
Страница 626: ...626 ...
Страница 640: ...640 ...
Страница 660: ...660 ...