Additional parameter data 383
28.12
Frequency ref2 source
-
-
1 = 1
28.13
Frequency ref1 function
0…5
-
1 = 1
28.14
Frequency ref1/2 selection
-
-
1 = 1
28.21
Constant frequency function
0000b…0011b
-
1 = 1
28.22
Constant frequency sel1
-
-
1 = 1
28.23
Constant frequency sel2
-
-
1 = 1
28.24
Constant frequency sel3
-
-
1 = 1
28.26
Constant frequency 1
-500.00 … 500.00
Hz
100 = 1 Hz
28.27
Constant frequency 2
-500.00 … 500.00
Hz
100 = 1 Hz
28.28
Constant frequency 3
-500.00 … 500.00
Hz
100 = 1 Hz
28.29
Constant frequency 4
-500.00 … 500.00
Hz
100 = 1 Hz
28.30
Constant frequency 5
-500.00 … 500.00
Hz
100 = 1 Hz
28.31
Constant frequency 6
-500.00 … 500.00
Hz
100 = 1 Hz
28.32
Constant frequency 7
-500.00 … 500.00
Hz
100 = 1 Hz
28.41
Frequency ref safe
-500.00…500.00
Hz
100 = 1 Hz
28.51
Critical frequency function
0000b…0011b
-
1 = 1
28.52
Critical frequency 1 low
-500.00…500.00
Hz
100 = 1 Hz
28.53
Critical frequency 1 high
-500.00…500.00
Hz
100 = 1 Hz
28.54
Critical frequency 2 low
-500.00…500.00
Hz
100 = 1 Hz
28.55
Critical frequency 2 high
-500.00…500.00
Hz
100 = 1 Hz
28.56
Critical frequency 3 low
-500.00…500.00
Hz
100 = 1 Hz
28.57
Critical frequency 3 high
-500.00…500.00
Hz
100 = 1 Hz
28.71
Freq ramp set selection
-
-
1 = 1
28.72
Freq acceleration time 1
0.000 …1800.000
s
1000 = 1 s
28.73
Freq deceleration time 1
0.000 …1800.000
s
1000 = 1 s
28.74
Freq acceleration time 2
0.000 …1800.000
s
1000 = 1 s
28.75
Freq deceleration time 2
0.000 …1800.000
s
1000 = 1 s
28.76
Freq ramp in zero source
-
-
1 = 1
28.77
Freq ramp hold
-
-
1 = 1
28.78
Freq ramp output balancing
-500.00…500.00
Hz
100 = 1 Hz
28.79
Freq ramp output balancing
enable
-
-
1 = 1
28.90
Frequency ref act 1
-500.00…500.00
Hz
100 = 1 Hz
28.91
Frequency ref act 2
-500.00…500.00
Hz
100 = 1 Hz
28.92
Frequency ref act 3
-500.00…500.00
Hz
100 = 1 Hz
28.96
Frequency ref act 7
-500.00…500.00
Hz
100 = 1 Hz
No.
Name
Type
Range
Unit
FbEq32
Содержание ACS880 ESP
Страница 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Страница 4: ......
Страница 28: ...28 PCP ESP control start up ...
Страница 30: ...30 Using the control panel ...
Страница 94: ...94 Standard programposi features ...
Страница 100: ...100 Default control connections ...
Страница 360: ...360 Parameters ...
Страница 362: ...362 Additional parameter data Fieldbus addresses Refer to the User s Manual of the fieldbus adapter ...
Страница 436: ...436 Fault tracing ...
Страница 486: ...486 Control chain diagrams ...
Страница 492: ...492 Appendix ESP with step up transformer and sine filter ...
Страница 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...