Additional parameter data 367
Parameter groups 10…99
07.26
Customization package
version
-
-
1 = 1
09 Pump actuals
09.01
Rod torque
-100000.00...100000.00
N•m or
lbft
100 = 1 Nm or
lbft
09.02
Maximum rod torque
-100000.00...100000.00
N•m or
lbft
100 = 1 Nm or
lbft
09.03
Motor torque
-100000.00...100000.00
N•m or
lbft
100 = 1 Nm or
lbft
09.04
Maximum motor torque
-100000.00...100000.00
N•m or
lbft
100 = 1 Nm or
lbft
09.05
Rod speed
-100000.00...100000.00
Prpm,
rpm or
Hz
100 = 1 Prpm,
rpm or Hz
09.06
Motor speed reference
-100000.00...100000.00
rpm or
Hz
100 = 1 rpm or
Hz
09.07
Run-time hours
0.00...100000.00
h
100 = 1 h
09.08
Fluid level
-100000.00...100000.00
m, ft or
Joints
100 = 1 m, ft or
Joints
09.09
Pressure
-100000.00...100000.00
kPa or
psi
100 = 1 kPa or
psi
09.10
Measured temperature
-100000.00...100000.00
°C
100 = 1 °C
09.11
Backspin speed reference
-100000.00...100000.00
Prpm,
rpm or
Hz
100 = 1 Prpm,
rpm or Hz
09.12
Start delay remain
0...4294967.295
s
1000 = 1 s
09.13
Backspin status word
0000h...FFFFh
-
1 = 1
09.14
Pump status word
0000h…FFFFh
-
1 = 1
09.15
Sleep feedback value
-100000.00...100000.00
Source
Unit
100 = 1
SourceUnit
09.16
Sleep time
0.000...10000.000
s
1000 = 1 s
No.
Name
Type
Range
Unit
FbEq32
10 Standard DI, RO
10.01
DI status
0000h…FFFFh
-
1 = 1
10.02
DI delayed status
0000h…FFFFh
-
1 = 1
10.03
DI force selection
0000h…FFFFh
-
1 = 1
10.04
DI force data
0000h…FFFFh
-
1 = 1
10.05
DI1 ON delay
0.0…3000.0
s
10 = 1 s
10.06
DI1 OFF delay
0.0…3000.0
s
10 = 1 s
10.07
DI2 ON delay
0.0…3000.0
s
10 = 1 s
10.08
DI2 OFF delay
0.0…3000.0
s
10 = 1 s
10.09
DI3 ON delay
0.0…3000.0
s
10 = 1 s
No.
Name
Type
Range
Unit
FbEq32
Содержание ACS880 ESP
Страница 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Страница 4: ......
Страница 28: ...28 PCP ESP control start up ...
Страница 30: ...30 Using the control panel ...
Страница 94: ...94 Standard programposi features ...
Страница 100: ...100 Default control connections ...
Страница 360: ...360 Parameters ...
Страница 362: ...362 Additional parameter data Fieldbus addresses Refer to the User s Manual of the fieldbus adapter ...
Страница 436: ...436 Fault tracing ...
Страница 486: ...486 Control chain diagrams ...
Страница 492: ...492 Appendix ESP with step up transformer and sine filter ...
Страница 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...