![ABB ACS880-34 Скачать руководство пользователя страница 189](http://html.mh-extra.com/html/abb/acs880-34/acs880-34_hardware-manual_2653189.webp)
Technical data 189
Derating for output voltage boosting
The drive can output a higher motor voltage than the supply voltage. This can require
derating of the drive output power depending on the difference between the supply voltage
and the output voltage to the motor for continuous operation.
This drawing shows the required derating for -3 and -5 (400 V and 500 V) drive types.
This drawing shows the required derating for -7 (690 V and 570 V) drive types.
P
N
Typical motor power in no-overload use.
I
Ld
Continuous rms output current allowing 10% overload for 1 minute every 5 minutes
P
Ld
Typical motor power for light-overload use.
I
Hd
Continuous rms output current allowing 50% overload for 1 minute every 5 minutes
*
Continuous rms output current allowing 40% overload for 1 minute every 5 minutes
U
Typical motor power in no-overload use
U
n
Nominal supply voltage of the drive. For -3 types
U
n
= 400 V, for -5 types
U
n
= 500 V. For -7
types
U
n
= 690 V but 575 V when
P
n
refers to nominal power ratings in the UL 575 V rating
tables.
P
Derated ouput power of the drive
P
n
Nominal power rating of the drive
0.80
0.85
0.90
0.95
1.00
1.05
1.10
1.10
1.05
1.00
0.95
0.90
0.85
0.80
0.75
0.70
P
/
P
n
U
/
U
n
0.80
0.85
0.90
0.95
1.00
1.05
1.10
1.10
1.05
1.00
0.95
0.90
0.85
0.80
0.75
0.70
P
/
P
n
U
/
U
n
Содержание ACS880-34
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 34 drive modules 132 to 400 kW 200 to 450 hp Hardware manual ...
Страница 4: ......
Страница 14: ...14 ...
Страница 22: ...22 Safety instructions ...
Страница 28: ...28 Introduction to the manual ...
Страница 42: ...42 Operation principle and hardware description ...
Страница 118: ...118 External control unit ...
Страница 140: ...140 Installation example with full cabling panels option H381 M8 16 Hex 2 5 4 3 1 1 1 1 2 6 7 ...
Страница 152: ...152 Installation checklist ...
Страница 156: ...156 Start up ...
Страница 158: ...158 Fault tracing ...
Страница 174: ...174 Maintenance ...
Страница 202: ...202 Technical data EU Declaration of Conformity Machinery Directive ...
Страница 204: ...204 Technical data ...
Страница 206: ...206 Dimension drawings Standard configuration 3AXD50000038012 ...
Страница 207: ...Dimension drawings 207 Location of power cable connection terminals with options H370 H356 3AXD50000038012 ...
Страница 208: ...208 Dimension drawings Drive module with options 0B051 H356 0H371 3AXD50000038012 ...
Страница 209: ...Dimension drawings 209 Configuration with option H381 3AXD50000323210 ...
Страница 210: ...210 Dimension drawings LCL filter module 3AXD50000206162 ...
Страница 214: ...214 Dimension drawings External control unit 3axd50000011687 ...
Страница 238: ...238 Resistor braking ...
Страница 242: ...242 du dt and sine filters ...
Страница 256: ...Contact us www abb com drives www abb com drivespartners 3AXD50000035191 Rev B EN 2018 09 28 ...