Control units of the drive
Contents of this chapter
This chapter
•
describes the connections of the control unit,
•
contains the specifications of the inputs and outputs of the control unit.
General
The BCU-x2 control unit is used with frame size R8i and multiples. The BCU-x2 consists of
a BCON-12 control board (and a BIOC-01 I/O connector board and power supply board)
built in a metal housing. The control unit is connected to the IGBT supply module(s) by fiber
optic cables.
In this manual, the name “BCU-x2” represents the control unit types BCU-02, BCU-12 and
BCU-22. These have a different number of power module connections (2, 7 and 12
respectively) but are otherwise similar.