Dimensions
Depth 2
Depth 1
Width 2
Width 1
Height 2
Height 1
Unit type
ACS880-
207-…
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
U
N
= 400 V (Range 380 … 415 V)
29.8
756
25
636
63.0
1600
39.4
1000
91.1
2315
84.5
2145
0420A-3
29.8
756
25
636
63.0
1600
39.4
1000
91.1
2315
84.5
2145
0580A-3
29.8
756
25
636
63.0
1600
39.4
1000
91.1
2315
84.5
2145
0810A-3
29.8
756
25
636
78.7
2000
-
-
91.1
2315
84.5
2145
1130A-3
29.8
756
25
636
78.7
2000
-
-
91.1
2315
84.5
2145
1330A-3
29.8
756
25
636
78.7
2000
-
-
91.1
2315
84.5
2145
1580A-3
34
864
29.3
744
102.4
2600
-
-
91.1
2315
84.5
2145
2350A-3
34
864
29.3
744
110.2
2800
-
-
91.1
2315
84.5
2145
3110A-3
34
864
29.3
744
157.5
4000
-
-
91.1
2315
84.5
2145
4620A-3
U
N
= 500 V (Range 380 … 500 V)
29.8
756
25
636
63.0
1600
39.4
1000
91.1
2315
84.5
2145
0400A-5
29.8
756
25
636
63.0
1600
39.4
1000
91.1
2315
84.5
2145
0530A-5
29.8
756
25
636
63.0
1600
39.4
1000
91.1
2315
84.5
2145
0730A-5
29.8
756
25
636
70.9
1800
-
-
91.1
2315
84.5
2145
1040A-5
29.8
756
25
636
78.7
2000
-
-
91.1
2315
84.5
2145
1420A-5
34
864
29.3
744
102.4
2600
-
-
91.1
2315
84.5
2145
2120A-5
34
864
29.3
744
110.2
2800
-
-
91.1
2315
84.5
2145
2800A-5
34
864
29.3
744
157.5
4000
-
-
91.1
2315
84.5
2145
4150A-5
U
N
= 690 V (Range 525 … 690 V)
29.8
756
25
636
63.0
1600
-
-
91.1
2315
84.5
2145
0310A-7
29.8
756
25
636
63.0
1600
-
-
91.1
2315
84.5
2145
0370A-7
29.8
756
25
636
63.0
1600
-
-
91.1
2315
84.5
2145
0540A-7
29.8
756
25
636
70.9
1800
-
-
91.1
2315
84.5
2145
0720A-7
29.8
756
25
636
70.9
1800
-
-
91.1
2315
84.5
2145
1050A-7
29.8
756
25
636
102.4
2600
-
-
91.1
2315
84.5
2145
1570A-7
34
864
29.3
744
110.2
2800
-
-
91.1
2315
84.5
2145
2070A-7
34
864
29.3
744
141.7
3600
-
-
91.1
2315
84.5
2145
3080A-7
34
864
29.3
744
200.1
5100
-
-
91.1
2315
84.5
2145
4100A-7
34
864
29.3
744
232.3
5900
-
-
91.1
2315
84.5
2145
5130A-7
Definitions
Normal height
Height 1
Height with IP54 roof
Height 2
Low power multidrive
Width 1
With auxiliary control cubicle and incoming cubicle(s)
Width 2
Without C128 Cooling air through bottom
Depth 1
If C128 Cooling air through bottom is selected due to extra air inlet channel at the
bottom
Depth 2
Technical data 125
Содержание ACS880-207
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 207 IGBT supply units Hardware manual ...
Страница 2: ......
Страница 4: ......
Страница 53: ... 3 3 Electrical installation 53 11 ...
Страница 54: ...3 54 Electrical installation ...
Страница 81: ...4 5 6 7 8 6 10 10 Maintenance 81 ...
Страница 94: ...5 6 10 3 4 7 9 8 94 Maintenance ...
Страница 99: ... Maintenance 99 ...
Страница 100: ... 100 Maintenance ...
Страница 103: ...5 6 3 4 8 9 7 Maintenance 103 ...
Страница 107: ...5 6 3 4 7 Maintenance 107 ...