![ABB ACS880-1604 Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/abb/acs880-1604/acs880-1604_hardware-manual_2645070.webp)
70 Electrical installation
Connection procedure for power connections inside the DC/DC
converter cubicle
For the cable types, see
Electrical planning instructions for ACS880 multidrive cabinets
and modules
(3AUA0000102324 [English]).
For the filter connections, see
Internal circuit diagram for the BDCL filter
.
WARNING!
Repeat the steps described in section
on page
. The complete safety instructions are given in
Safety instructions for ACS880 multidrive cabinets and modules
(3AUA0000102301 [English]). If you ignore them, injury or death, or
damage to the equipment can occur.
WARNING!
With aluminum cables, apply grease to stripped conductors before
attaching them to non-coated aluminum cable lugs. Obey the grease
manufacturer’s instructions. Aluminum-aluminum contact can cause oxidation in
the contact surfaces.
1. Repeat the steps described in section
2. Open the door of the DC/DC converter cubicle and remove the shrouding (if any).
3. Make the connections in between the main circuit components inside the cabinet if not
done yet. Do the connections according to the final circuit diagrams for the drive. If the
connections are ready, check them against the final circuit diagrams. Do not use the
example circuit diagrams in this manual as the sole source of information when doing
or checking the connections.
For the tightening torques, see
on page
4. Ground the modules by the top edge of the front plate. The grounding point is marked
on the module (a). Connect the front plate to the frame support bracket (b) with
screws. The frame support bracket should have a galvanic connection to the PE
busbar through the cabinet frame.
Note:
If the cabinet frame is painted (for example, Rittal TS 8 enclosures), it is
important to make sure that a good galvanic connection to ground (PE busbar) is
achieved. You can, for example, remove the paint from the connection points and use
star washers.
Note:
The connection to ground merely through the mounting screws and the cabinet
chassis is not always good enough. To ensure the continuity of the protective bonding
circuit, you can connect the modules to the cabinet PE busbar with a copper busbar or
cable. The inductance and impedance of the PE conductor must be rated according to
permissible touch voltage appearing under fault conditions (so that the fault point
voltage will not rise excessively when a ground fault occurs). See
Electrical planning
instructions for ACS880 multidrive cabinets and modules
(3AUA0000102324
[English]).
Содержание ACS880-1604
Страница 1: ...ABB industrial drives Hardware manual ACS880 1604 DC DC converter modules ...
Страница 4: ......
Страница 12: ...12 ...
Страница 36: ...36 Operation principle and hardware description ...
Страница 45: ...Cabinet construction 45 Kits for DDC R8i unit in 800 mm Rittal TS 8 enclosure ...
Страница 46: ...46 Cabinet construction Stage 1 Installation of common parts ...
Страница 47: ...Cabinet construction 47 Stage 2 Module and bottom cable entry installation parts ...
Страница 48: ...48 Cabinet construction Stage 3 Busbars and quick connectors for connecting DDC module and filter ...
Страница 49: ...Cabinet construction 49 Stage 4A DC connection with charging ...
Страница 50: ...50 Cabinet construction Stage 4B DC connection without charging ...
Страница 51: ...Cabinet construction 51 Stage 5A DC connection with charging ...
Страница 52: ...52 Cabinet construction Stage 5B DC connection without charging ...
Страница 53: ...Cabinet construction 53 Stage 6 DDC and energy storage connection ...
Страница 54: ...54 Cabinet construction Stage 7 Control unit mounting plate ...
Страница 55: ...Cabinet construction 55 Stage 8 DDC shroud installation ...
Страница 56: ...56 Cabinet construction Stage 9 DDC module and filter installation ...
Страница 58: ...58 Cabinet construction Kits for DDC R8i unit in 800 mm wide generic enclosure ...
Страница 64: ...64 Guidelines for planning electrical installation ...
Страница 71: ...Electrical installation 71 5 Refit any shrouding removed earlier and close the cubicle doors 4 a b b ...
Страница 80: ...80 Electrical installation ...
Страница 97: ...Maintenance 97 7 3 4 5 6 ...
Страница 99: ...Maintenance 99 3 4 5 6 7 8 9 9 ...
Страница 102: ...102 Maintenance 12 Install and tighten the two screws 10 11 12 ...
Страница 108: ...108 Maintenance 6 6 6 7 5 4 ...
Страница 109: ...Maintenance 109 8 9 8 ...
Страница 112: ...112 Maintenance 4 4 ...
Страница 113: ...Maintenance 113 6 6 5 7 7 8 ...
Страница 170: ...170 Dimension drawings R8i DC DC converter module ...
Страница 171: ...Dimension drawings 171 ...
Страница 172: ...172 Dimension drawings Quick connectors of the DC DC converter module ...
Страница 173: ...Dimension drawings 173 Quick connectors Dimensions in mm 1 mm 0 0394 in ...
Страница 174: ...174 Dimension drawings BDCL filter module ...
Страница 176: ...176 Dimension drawings BCU control unit ...
Страница 177: ...Dimension drawings 177 BAMU voltage current measurement unit ...
Страница 179: ...Dimension drawings 179 Ramp Dimensions in mm 1 mm 0 0394 in ...
Страница 180: ...180 Dimension drawings Dimensions in mm 1 mm 0 0394 in ...
Страница 181: ...Dimension drawings 181 Internal cabinet fan W2E 143 AA09 01 W2E 143 AA15 01 Air flow ...
Страница 185: ...Dimension drawings 185 Charging controller BSFC 02C SWITCH FUSE CONTROLLER 79 3 11 247 9 72 66 5 2 62 ...
Страница 190: ...190 Dimension drawings ...
Страница 194: ...194 Example circuit diagrams ...
Страница 222: ...www abb com drives www abb com drivespartners 3AXD50000023642 Rev B EN 2017 02 08 Contact us ...