Operation principle
The ACS880-11 is a four-quadrant drive for controlling asynchronous AC induction
motors, AC induction servomotors, permanent magnet motors and synchronous
reluctance motors.
The drive includes a line-side converter and a motor-side converter. The parameters
and signals for both converters are combined into one primary user program.
The figure below shows the simplified main circuit diagram of the drive.
T1/U
T2/V
T3/W
4
2
1
3
L1
L2
L3
5
UDC+ UDC-
A
Drive
A
LCL filter
1
Line-side converter
2
DC link. DC circuit between the line-side converter and motor-side converter.
3
Motor-side converter
4
Common mode filter (E208)
5
The line-side converter rectifies three phase AC current to direct current for the
intermediate DC link of the drive. The intermediate DC link further supplies the motor-side
converter that runs the motor.
Both converters consist of six insulated gate bipolar transistors (IGBT) with free wheeling
diodes. The content of AC voltage and current harmonics is low. The LCL filter
suppresses the harmonics further.
The line-side converter can transfer energy from the electrical power system to the drive
DC link and vice versa. Thus the drive can operate the motor in all four quadrants (speed,
torque). The figure below visualizes the operation of the four-quadrant drive. In quadrants
I and III, the drive operates in the motoring mode and takes energy from the power
system. In quadrants II and IV, the drive operates in generating mode, and regenerates
energy back to the power system.
28 Operation principle and hardware description
Содержание ACS880-11
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 11 drives Hardware manual ...
Страница 2: ......
Страница 4: ......
Страница 26: ...26 ...
Страница 52: ...52 ...
Страница 82: ...82 ...
Страница 95: ...R6 R8 IP21 R6 R8 IP55 Electrical installation IEC 95 ...
Страница 103: ...R6 1 5 N m 0 5 N m Electrical installation IEC 103 ...
Страница 104: ...R8 1 5 N m 0 5 0 6 N m 104 Electrical installation IEC ...
Страница 112: ...With FDPI 02 modules OPEN TERMIN ATED 1 1 2 2 OPEN TERMINATED 3 112 Electrical installation IEC ...
Страница 116: ...R6 R8 UL Type 1 R6 R8 UL Type 12 116 Electrical installation North America NEC ...
Страница 120: ...R3 7 7 8 8 L1 L2 L3 T1 U T2 V T3 W PE Ground 1 7 N m 1 2 lbf ft 120 Electrical installation North America NEC ...
Страница 142: ...142 ...
Страница 154: ... Fan arrow must point up 154 Maintenance ...
Страница 160: ...160 ...
Страница 181: ... Package dimensions R6 R3 R8 Technical data 181 ...
Страница 202: ...R3 IP21 UL Type 1 3AXD50000045323 202 Dimension drawings ...
Страница 203: ...R3 Option B056 IP55 UL Type 12 3AXD50000045322 Dimension drawings 203 ...
Страница 204: ...R6 IP21 UL Type 1 3AXD50000045353 204 Dimension drawings ...
Страница 205: ...R6 Option B056 IP55 UL Type 12 3AXD50000045352 Dimension drawings 205 ...
Страница 206: ...R8 IP21 UL Type 1 3AXD50000047667 206 Dimension drawings ...
Страница 207: ...R8 Option B056 IP55 UL Type 12 3AXD50000047667 Dimension drawings 207 ...
Страница 208: ...208 ...
Страница 225: ... Declarations of conformity The Safe torque off function 225 ...