![ABB ACS880-04FXT Скачать руководство пользователя страница 63](http://html.mh-extra.com/html/abb/acs880-04fxt/acs880-04fxt_hardware-manual_3309063.webp)
Modern variable speed drives with their fast rising voltage pulses and high switching
frequencies can generate current pulses that flow through the motor bearings. This can
gradually erode the bearing races and rolling elements.
d
u
/d
t
filters protect motor insulation system and reduce bearing currents. Common mode
filters mainly reduce bearing currents. Insulated N-end (non-drive end) bearings protect the
motor bearings.
■
Requirements table
These tables show how to select the motor insulation system and when a drive d
u
/d
t
and
common mode filters and insulated N-end (non-drive end) motor bearings are required.
Ignoring the requirements or improper installation may shorten motor life or damage the
motor bearings and voids the warranty.
This table shows the requirements when an ABB motor is in use.
Requirement for
Nominal AC supply
voltage
Motor
type
ABB du/dt and common mode filters, insulated N-end
motor bearings
Motor insula-
tion system
P
N
≥ 350 kW
or
frame size ≥ IEC 400
100 kW ≤ P
N
< 350
kW
or
IEC 315 ≤ frame size
< IEC 400
P
N
< 100 kW
and frame
size <
IEC 315
P
N
≥ 469 hp
or
frame size >
NEMA 580
134 hp ≤ P
N
< 469 hp
or
NEMA 500 ≤ frame
size ≤ NEMA 580
P
N
< 134 hp
and frame
size <
NEMA 500
+ N + CMF
+ N
-
Standard
U
N
≤ 500 V
Random-
wound
M2_, M3_
and M4_
+ N + d
u
/d
t
+ CMF
+ N + d
u
/d
t
+ d
u
/d
t
Standard
500 V <
U
N
≤ 600 V
or
+ N + CMF
+ N
-
Reinforced
+ N + d
u
/d
t
+ CMF
+ N + d
u
/d
t
+ d
u
/d
t
Reinforced
600 V <
U
N
≤ 690 V
(cable length ≤
150 m)
+ N + CMF
+ N
-
Reinforced
600 V <
U
N
≤ 690 V
(cable length >
150 m)
P
N
< 500 kW:
+N + CMF
+ N + CMF
n.a.
Standard
380 V <
U
N
≤ 690 V
Form-
wound
HX_ and
AM_
P
N
≥ 500 kW:
+N + d
u
/d
t
+ CMF
+ N + d
u
/d
t
with voltages over 500 V + CMF
Check with the
motor manu-
facturer.
380 V <
U
N
≤ 690 V
Old
1)
form-
wound
HX_ and
modular
+ N + CMF
Enamelled
wire with fiber
glass taping
0 V <
U
N
≤ 500 V
Random-
wound
HX_ and
AM_
2)
+ N + d
u
/d
t
+ CMF
500 V <
U
N
≤ 690 V
Consult the motor manufacturer.
HDP
1) manufactured before 1.1.1998
Guidelines for planning the electrical installation 63
Содержание ACS880-04FXT
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 04FXT drive module packages Hardware manual ...
Страница 2: ......
Страница 4: ......
Страница 40: ...40 ...
Страница 54: ...54 ...
Страница 82: ...82 ...
Страница 86: ...M10 86 Electrical installation ...
Страница 106: ...106 ...
Страница 114: ...FSO xx safety functions module connection X12 See the user manual of the FSO xx module 114 Control unit of the drive ...
Страница 118: ...118 ...
Страница 122: ...122 ...
Страница 132: ...132 ...
Страница 136: ...136 ...
Страница 158: ...158 ...
Страница 160: ...Standard configuration IP00 UL Type Open 160 Dimension drawings ...
Страница 161: ...Drive module with optional support brackets IP00 UL Type Open Dimension drawings 161 ...
Страница 162: ...Drive module with optional full size input and output power cable terminals and IP20 shrouds 162 Dimension drawings ...
Страница 163: ...Mounting plate opening 3AXD50000038119 Dimension drawings 163 ...
Страница 164: ...3AXD50000038119 164 Dimension drawings ...
Страница 182: ... Declaration of conformity 182 The Safe torque off function ...
Страница 183: ...The Safe torque off function 183 ...
Страница 184: ...184 ...