Fault tracing 363
2330
Earth leakage
Drive has detected load
unbalance typically due to
earth fault in motor or motor
cable.
If the control unit is externally powered,
check the setting of parameter
.
Check there are no power factor
correction capacitors or surge absorbers
in motor cable.
Check for an earth fault in motor or motor
cables by measuring the insulation
resistances of motor and motor cable.
Try running the motor in scalar control
mode if allowed. (See parameter
.)
With parallel-connected modules, check
the auxiliary code (format XXXY YYZZ).
“Y YY” specifies through which BCU
control unit channel the fault was
received.
If no earth fault can be detected, contact
your local ABB representative.
2340
Short circuit
Short-circuit in motor cable(s)
or motor
Check motor and motor cable for cabling
errors.
If the control unit is externally powered,
check the setting of parameter
.
Check that parameter
Check there are no power factor
correction capacitors or surge absorbers
in motor cable.
Check the auxiliary code (format XXXY
YYZZ). With parallel-connected inverter
modules, “Y YY” specifies through which
BCU control unit channel the fault was
received. “ZZ” indicates the location of
the short circuit (
0:
No detailed
information available,
1:
Upper branch of
U-phase,
2:
Lower branch of U-phase,
4:
Upper branch of V-phase,
8:
Lower
branch of V-phase,
10:
Upper branch of
W-phase,
20:
Lower branch of W-phase,
other:
combinations of the above).
After correcting the cause of the fault,
reboot the control unit (using parameter
) or by cycling
power.
2381
IGBT overload
Excessive IGBT junction to
case temperature. This fault
protects the IGBT(s) and can
be activated by a short circuit
in the motor cable.
Check motor cable.
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Check motor power against drive power.
Code
(hex)
Fault
Cause
What to do
Содержание ACS860
Страница 1: ... ABB INDUSTRIAL DRIVES ACS860 primary control program Firmware manual ...
Страница 4: ......
Страница 10: ...10 Table of contents ...
Страница 18: ...18 Using the control panel ...
Страница 24: ...24 Control locations and operating modes ...
Страница 54: ...54 Program features ...
Страница 78: ...78 Program features ...
Страница 90: ...90 Application macros ...
Страница 342: ...342 Additional parameter data ...
Страница 380: ...380 Fault tracing ...
Страница 381: ...Fault tracing 381 ...
Страница 382: ...382 Fault tracing ...
Страница 436: ...436 Control chain diagrams ...