Additional parameter data 333
58.11 UART errors
0…4294967295
-
1 = 1
58.12 CRC errors
0…4294967295
-
1 = 1
58.14 Communication loss action
0…5
-
1 = 1
58.15 Communication loss mode
1…2
-
1 = 1
58.16 Communication loss time
0.0 … 6000.0
s
10 = 1 s
58.17 Transmit delay
0…65535
ms
1 = 1 ms
58.18 EFB control word
0000h…FFFFh
-
1 = 1
58.19 EFB status word
0000h…FFFFh
-
1 = 1
58.25 Control profile
0, 2
-
1 = 1
58.26 EFB ref1 type
0…5
-
1 = 1
58.27 EFB ref2 type
0…5
-
1 = 1
58.28 EFB act1 type
0…6
-
1 = 1
58.29 EFB act2 type
0…6
-
1 = 1
58.30 EFB status word transparent
source
-
-
1 = 1
58.31 EFB act1 transparent source
-
-
1 = 1
58.32 EFB act2 transparent source
-
-
1 = 1
58.33 Addressing mode
0…2
-
1 = 1
58.34 Word order
0…1
-
1 = 1
58.36 EFB comm supervision force
0000h…FFFFh
-
1 = 1
58.101 Data I/O 1
-
-
1 = 1
58.102 Data I/O 2
-
-
1 = 1
58.103 Data I/O 3
-
-
1 = 1
58.104 Data I/O 4
-
-
1 = 1
58.105 Data I/O 5
-
-
1 = 1
58.106 Data I/O 6
-
-
1 = 1
58.107 Data I/O 7
-
-
1 = 1
…
…
…
…
…
58.124 Data I/O 24
-
-
1 = 1
60 DDCS communication
60.01 M/F communication port
-
-
-
60.02 M/F node address
1…254
-
-
60.03 M/F mode
0…6
-
-
60.05 M/F HW connection
0…1
-
-
60.08 M/F comm loss timeout
0…65535
ms
-
60.09 M/F comm loss function
0…3
-
-
60.10 M/F ref1 type
0…5
-
-
60.11 M/F ref2 type
0…5
-
-
60.12 M/F act1 type
0…5
-
-
60.13 M/F act2 type
0…5
-
-
60.14 M/F follower selection
0…16
-
-
No.
Name
Type
Range
Unit
FbEq32
Содержание ACS860
Страница 1: ... ABB INDUSTRIAL DRIVES ACS860 primary control program Firmware manual ...
Страница 4: ......
Страница 10: ...10 Table of contents ...
Страница 18: ...18 Using the control panel ...
Страница 24: ...24 Control locations and operating modes ...
Страница 54: ...54 Program features ...
Страница 78: ...78 Program features ...
Страница 90: ...90 Application macros ...
Страница 342: ...342 Additional parameter data ...
Страница 380: ...380 Fault tracing ...
Страница 381: ...Fault tracing 381 ...
Страница 382: ...382 Fault tracing ...
Страница 436: ...436 Control chain diagrams ...