136 Parameters
Fieldbus A
The start and stop commands are taken from fieldbus adapter
A.
Note:
The start signal is always level-triggered with this
setting regardless of parameter
12
Embedded fieldbus
The start and stop commands are taken from the embedded
fieldbus interface.
Note:
The start signal is always level-triggered with this
setting regardless of parameter
14
M/F link
The start and stop commands are taken from another drive
through the master/follower link.
Note:
The start signal is always level-triggered with this
setting regardless of parameter
15
Application
Program
The start and stop commands are taken from the application
program control word (parameter
).
Note:
The start signal is always level-triggered with this
setting regardless of parameter
21
ATF
Reserved.
22
DDCS controller
The start and stop commands are taken from an external
(DDCS) controller.
Note:
The start signal is always level-triggered with this
setting regardless of parameter
16
Defines whether the start signal for external control location
EXT1 is edge-triggered or level-triggered.
Note:
This parameter is only effective when parameter
is set to
.
Edge
The start signal is edge-triggered.
0
Level
The start signal is level-triggered.
1
Selects source 1 for parameter
.
Not selected
0 (always off).
0
Selected
1 (always on).
1
DI1
Digital input DI1 (
, bit 0).
2
DI2
Digital input DI2 (
, bit 1).
3
DI3
Digital input DI3 (
, bit 2).
4
DI4
Digital input DI4 (
, bit 3).
5
DI5
Digital input DI5 (
, bit 4).
6
DI6
Digital input DI6 (
, bit 5).
7
DIO1
Digital input/output DIO1 (
, bit 0).
10
DIO2
Digital input/output DIO2 (
, bit 1).
11
-
Selects source 2 for parameter
.
For the available selections, see parameter
Selects source 3 for parameter
.
For the available selections, see parameter
No.
Name/Value
Description
Def
/
FbEq16
Содержание ACS860
Страница 1: ... ABB INDUSTRIAL DRIVES ACS860 primary control program Firmware manual ...
Страница 4: ......
Страница 10: ...10 Table of contents ...
Страница 18: ...18 Using the control panel ...
Страница 24: ...24 Control locations and operating modes ...
Страница 54: ...54 Program features ...
Страница 78: ...78 Program features ...
Страница 90: ...90 Application macros ...
Страница 342: ...342 Additional parameter data ...
Страница 380: ...380 Fault tracing ...
Страница 381: ...Fault tracing 381 ...
Страница 382: ...382 Fault tracing ...
Страница 436: ...436 Control chain diagrams ...