![ABB ACS850-04 series Скачать руководство пользователя страница 239](http://html1.mh-extra.com/html/abb/acs850-04-series/acs850-04-series_firmware-manual_3365228239.webp)
Additional parameter data 239
32-bit integer bit pointers
When a bit pointer parameter is connected to value 0 or 1, the format is as follows:
When a bit pointer parameter is connected to a bit value of another parameter, the
format is as follows:
When a bit pointer parameter is connected to a solution program, the format is as
follows:
Note:
Bit pointer parameters connected to a solution program are read-only via
fieldbus.
Bit
30…31
16…29
0
Name
Source type
Not in use
Value
Value
0
-
0…1
Description
Bit pointer is connected
to 0/1.
-
0 = False, 1 = True
Bit
30…31
24…29
16…23
8…15
0…7
Name
Source type
Not in use
Bit sel
Group
Index
Value
1
-
0…31
2…255
1…255
Description
Bit pointer is
connected to
signal bit
value.
-
Bit selection
Group of
source
parameter
Index of
source
parameter
Bit
30…31
24…29
0…23
Name
Source type
Bit sel
Address
Value
2
0…31
0…2
23
Description
Bit pointer is connected
to solution program.
Bit selection
Relative address of
solution program
variable
Содержание ACS850-04 series
Страница 1: ...ACS850 Firmware Manual ACS850 Standard Control Program...
Страница 4: ......
Страница 10: ...10 Table of contents...
Страница 52: ...52 The ACS850 control panel...
Страница 56: ...56 Control locations and operating modes...
Страница 80: ...80 Program features...
Страница 236: ...236 Parameters...
Страница 286: ...286 Fieldbus control...
Страница 294: ...294 Control block diagrams...