76 Electrical installation
Connection procedure – a blank plate at the cable lead-through
For description of the blank plate, see chapter
Operation principle and hardware
, page
WARNING!
Read and follow the instructions given in chapter
.
Ignoring the instructions can cause physical injury or death, or damage to the
equipment.
1. Open the door of the inverter module cubicle.
2. Remove the shroud that protects the rotor cable connection busbars and cable
entries.
3. Remove the fans (see the pictures below). Undo the two fastening screws of the fan
collar, push the collar a bit inwards and pull the fan with collar out.
4. Cut/drill suitable holes for the cables. Smooth the hole edges.
5. Lead the cables inside the cabinet through the lead-through plate holes. Mind the
edges.
6. Seal the cable lead-throughs to retain the degree of protection of the enclosure (to
keep the dust and humidity out of the cabinet).
7. Connect the cables to the appropriate busbars. See section
. For
the tightening torques, see chapter
.
Note:
Only use lead-through components that fulfill the requirements of degree of
protection IP54 or higher.
Connection procedure – sealing modules at the cable lead-through
For description of the sealing modules, see chapter
Operation principle and hardware
, page
WARNING!
Read and follow the instructions given in chapter
.
Ignoring the instructions can cause physical injury or death, or damage to the
equipment.
1. Open the door of the inverter module cubicle.
2. Remove the shroud that protects the rotor cable connection busbars and cable
entries.
3. Remove the fans (see the pictures below). Undo the two fastening screws of the fan
collar, push the collar a bit inwards and pull the fan with collar out.
4. Follow the instructions given on page
.
Содержание ACS800-67LC
Страница 1: ... ABB WIND TURBINE CONVERTERS ACS800 67LC wind turbine converters Hardware manual ...
Страница 4: ......
Страница 16: ...16 Safety instructions ...
Страница 22: ...22 Introduction to the manual ...
Страница 42: ...42 Operation principle and hardware description ...
Страница 52: ...52 Mechanical installation ...
Страница 79: ...Electrical installation 79 3 3 Rotor side cable connection terminals U2 V2 W2 ...
Страница 92: ...92 Maintenance 4 6 5 5 ...
Страница 103: ...Maintenance 103 Bussmann fuses Mersen fuses ...
Страница 109: ...Maintenance 109 5 6 7 ...
Страница 131: ...Technical data 131 Declaration of incorporation ...
Страница 136: ...136 Dimension drawings ACS800 67LC 1075 0575 7 and 1375 0575 7 ...
Страница 137: ...Dimension drawings 137 With 400 mm wide incoming cubicle option C111 ...
Страница 138: ...138 Dimension drawings ACS800 67LC 1375 1125 7 ...
Страница 139: ...Dimension drawings 139 With 400 mm wide incoming cubicle option C111 ...
Страница 140: ...140 Dimension drawings ACS800 67LC 1595 0865 7 and 2035 1125 7 ...
Страница 141: ...Dimension drawings 141 With 400 mm wide incoming cubicle option C111 ...
Страница 143: ...Dimension drawings 143 Options 2H370 and C111 Option 1H371 ...
Страница 144: ...144 Dimension drawings Options 1H371 and C111 Options 2H371 and C111 ...
Страница 145: ...Dimension drawings 145 Option H378 Options H378 and C111 ...
Страница 147: ...Dimension drawings 147 Option 2H372 ...
Страница 148: ...148 Dimension drawings Option 3H372 ...
Страница 149: ...Dimension drawings 149 Option 1H373 ...
Страница 150: ...150 Dimension drawings Option 2H373 ...
Страница 151: ...Dimension drawings 151 Option 3H373 ...
Страница 152: ...152 Dimension drawings Option H375 ...