Practical examples 85
Generator nominal power calculation
Generator values must be given at 50 Hz (60 Hz). These values are not equal to the wind
turbine nominal values. Wind turbine nominal power is achieved with 100% torque
reference at the nominal wind turbine speed.
Calculate the generator nominal power with the following equation.
Example:
Nominal operating point: Wind turbine nominal power is 1600 kW, wind turbine nominal
speed is 1770 rpm and generator nominal speed is 1511 rpm.
With 100% torque reference at 1770 rpm, the wind turbine output is 1600 kW, when
parameter 99.06 MOTOR NOM POWER value is
99.06 MOTOR NOM POWER = (1511 rpm
·
1600 kW) / 1770 rpm = 1365 kW.
Setting the equivalent circuit values to the parameters
When the equivalent circuit values are given for star connection and the rotor values are
reduced to the stator reference frame, the equivalent circuit values are set to the
parameters as shown in the table below.
Note:
If the equivalent circuit values are given for delta connection, the values for
parameters 99.21 Rs, 99.22 X1S, 99.23 X2S, 99.24 XM and 99.25 Rr must be divided by
three.
X2 ’ and
R
2
’
must be reduced to the stator reference frame. Reducing is marked with ‘
and it is calculated as shown below.
Parameter
Equivalent circuit value
Often marked as
99.21 Rs
R
s
R
1
99.22 X1S
X
s
×
X1
99.23 X2S
X
r
×
Xr ’
99.24 XM
X
m
×
X
h
99.25
Rr
R
r
R
2
’
99.06 MOTOR NOM POWER
99.05 MOTOR NOM SPEED Wind turbine nom. power
⋅
Wind turbine nom. speed
----------------------------------------------------------------------------------------------------------------------------------------------------
=
ı
ı
ı
=
99.23 X2S
X2
ı
2
=
99.25 Rr
R
2
99.15 MOTOR OPEN CKT V
99.02 MOTOR NOM VOLTAGE
2
99.15 MOTOR OPEN CKT V
99.02 MOTOR NOM VOLTAGE
Содержание ACS800-67
Страница 1: ...ABB wind turbine converters System description and start up guide ACS800 67 wind turbine converters ...
Страница 4: ......
Страница 76: ...76 Start up with medium voltage stator ...
Страница 99: ...Practical examples 99 1 4 4 3 2 5 6 7 ...
Страница 106: ...106 Practical examples Counterclockwise rotation at drive end D end Power cabinet Encoder ...
Страница 118: ...118 Tracing the source of warnings limits and faults ...
Страница 120: ...Contact us www abb com windconverters 3AUA0000095094 Rev B EN 2017 12 31 ...