Technical data
169
UL marking
The drive is
cULus listed and cCSAus certified. The approvals are valid with rated
voltages up to 600 V. The markings are attached to the drives when oC129
(cULus) or +C134 (cCSAus) are selected.
UL checklist
Input power connection
– Short-circuit current protection (UL 508A): The drive is
suitable for use in a circuit capable of delivering not more than 100,000 symmetrical
amperes (rms) at 600 V maximum when protected with the fuses given in section
, page
Disconnecting device (disconnecting means)
, page
Ambient conditions
– The drive is to be used in a heated indoor controlled
environment. For the specifications, see
.
Input cable fuses
– For installation in the United States, branch circuit protection
must be provided in accordance with National Electrical Code (NEC) and any
applicable local codes. To fulfil this requirement, use the US fuses given in section
, page
For installation in Canada, branch circuit protection must be provided in accordance
with Canadian Electrical Code and any applicable provincial codes. To fulfil this
requirement, use the UL classified fuses given in section
, page
Power cable selection
Planning the electrical installation
, page
.
Power cable connections
– For the connection diagram and tightening torques,
.
Control connections
– For the connection diagram and tightening torques, see
.
Overload protection
– The drive provides overload protection in accordance with
the National Electrical Code (US). See the
Firmware Manual
for setting. Default
setting is off, must be activated at start-up.
Brake unit
– The drive can be equipped with a brake unit that will allow the drive to
dissipate regenerative energy (normally associated with quickly decelerating a
motor).
UL standards
– See
on page
.
CSA marking
The ACS800-17LC is CSA marked.
Approvals
The ACS800-17LC+C121 units are type approved by American Bureau of Shipping,
Det Norske Veritas and Lloyd’s Register of Shipping.
Содержание ACS800-17LC
Страница 1: ...ABB industrial drives Hardware manual ACS800 17LC Drives 55 to 5200 kW ...
Страница 4: ......
Страница 10: ...Update notice 6 ...
Страница 18: ...Table of contents 12 ...
Страница 26: ...Safety instructions 20 ...
Страница 32: ...Introduction to the manual 26 ...
Страница 60: ...Hardware description 54 ...
Страница 74: ...Mechanical installation 68 ...
Страница 114: ...Electrical installation 108 ...
Страница 142: ...Maintenance 136 ...
Страница 150: ...Internal cooling circuit 144 ...
Страница 179: ...Dimensions 173 Frame sizes R7i R7i and R8i R8i bottom entry exit ...
Страница 180: ...Dimensions 174 Frame sizes R7i R7i and R8i R8i marine units C121 ...
Страница 182: ...www abb com drives www abb com drivespartners Contact us 3AUA0000065339 Rev B EN 2016 06 07 ...