Installation checklist
109
Installation checklist
What this chapter contains
This chapter contains an installation checklist.
Installation checklist
Check the mechanical and electrical installation of the drive before start-up. Go
through the checklist together with another person.
WARNING!
Only qualified electricians are allowed to carry out the work described
below. Follow the complete safety instructions of the drive. Ignoring the safety
instructions can cause injury or death.
Open the main disconnector of the drive and lock it to open position.
Ensure by measuring that the drive is not powered.
Check that …
The drive cabinet has been fixed to floor, and if necessary (due to vibration etc.), also from top
to the wall or roof.
The ambient operating conditions meet the specification in chapter
If the drive will be connected to an IT (ungrounded) or a corner grounded TN supply network:
The varistors and EMC filter of the drive (if any) have been disconnected. See chapter
If the drive has been stored over one year: The electrolytic DC capacitors in the DC link of the
drive have been reformed. See the separate reforming instructions (available in the Internet of
from a local ABB representative).
There is an adequately sized protective ground conductor between the drive and the
switchboard.
There is an adequately sized protective ground conductor between the motor and the drive.
All protective ground conductors have been connected to the appropriate terminals and the
terminals have been tightened (pull conductors to check).
The supply voltage matches the nominal input voltage of the drive. Check the type
designation label.
The input power cable has been connected to appropriate terminals, the phase order is right,
and the terminals have been tightened (pull conductors to check).
The motor cable has been connected to appropriate terminals, the phase order is right, and
the terminals have been tightened (pull conductors to check).
The brake resistors (present only with D151) has been connected to appropriate
terminals, and the terminals have been tightened (pull conductors to check).
The voltage setting of the auxiliary voltage transformer T10 (if any) meet the supply voltage.
Содержание ACS800-17LC
Страница 1: ...ABB industrial drives Hardware manual ACS800 17LC Drives 55 to 5200 kW ...
Страница 4: ......
Страница 10: ...Update notice 6 ...
Страница 18: ...Table of contents 12 ...
Страница 26: ...Safety instructions 20 ...
Страница 32: ...Introduction to the manual 26 ...
Страница 60: ...Hardware description 54 ...
Страница 74: ...Mechanical installation 68 ...
Страница 114: ...Electrical installation 108 ...
Страница 142: ...Maintenance 136 ...
Страница 150: ...Internal cooling circuit 144 ...
Страница 179: ...Dimensions 173 Frame sizes R7i R7i and R8i R8i bottom entry exit ...
Страница 180: ...Dimensions 174 Frame sizes R7i R7i and R8i R8i marine units C121 ...
Страница 182: ...www abb com drives www abb com drivespartners Contact us 3AUA0000065339 Rev B EN 2016 06 07 ...