Electrical installation
103
Connecting the control cables for the inverter unit
Default I/O connection diagram
X2*
RMIO
X20
X20
1
1
VREF-
Reference voltage -10 V DC, 1 kohm <
R
L
< 10 kohm
2
2
AGND
X21
X21
1
1
VREF+ Reference voltage 10 V DC, 1 kohm <
R
L
<
10 kohm
2
2
AGND
3
3
AI1+
Speed reference 0(2)... 10 V,
R
in
>
200 kohm
4
4
AI1-
5
5
AI2+
By default, not in use. 0(4)... 20 mA
, R
in
=
100 ohm
6
6
AI2-
7
7
AI3+
By default, not in use. 0(4)... 20 mA
, R
in
=
100 ohm
8
8
AI3-
9
9
AO1+
Motor speed 0(4)...20 mA 0...motor nom.
speed,
R
L
< 700 ohm
10
10
AO1-
11
11
AO2+
Output current 0(4)...20 mA 0...motor
nom. current,
R
L
< 700 ohm
12
12
AO2-
X22
X22
1
1
DI1
Stop/Start
2
2
DI2
Forward/Reverse
1)
3
3
DI3
Not in use
4
4
DI4
Acceleration & deceleration select
2)
5
5
DI5
Constant speed select
3)
6
6
DI6
Constant speed select
3)
7
7
+24VD
+24 V DC max. 100 mA
8
8
+24VD
9
9
DGND1 Digital ground
10
10
DGND2 Digital ground
11
11
DIIL
Start interlock (0 = stop)
4)
X23
X23
1
1
+24V
Auxiliary voltage output and input, non-
isolated, 24 V DC 250 mA
5)
2
2
GND
X25
X25
1
1
RO1
Relay output 1: ready
2
2
RO1
3
3
RO1
X26
X26
1
1
RO2
Relay output 2: running
2
2
RO2
3
3
RO2
X27
X27
1
1
RO3
Relay output 3: fault (-1)
2
2
RO3
3
3
RO3
=
=
Fault
A
rpm
* optional terminal block (not in all units)
1)
Only effective if par. 10.03 is set to
REQUEST by the user.
2)
0 = open, 1 = closed
3)
See par. group 12 CONSTANT
SPEEDS.
4)
See parameter 21.09 START INTRL
FUNC.
5)
Total maximum current shared
between this output and optional
modules installed on the board.
DI4 Ramp times according to
0
parameters 22.02 and 22.03
1
parameters 22.04 and 22.05
DI5 DI6 Operation
0
0
Set speed through AI1
1
0
Constant speed 1
0
1
Constant speed 2
1
1
Constant speed 3
RMIO
Terminal block size:
cables 0.3 to 3.3 mm
2
(22 to 12 AWG)
Tightening torque:
0.2 to 0.4 Nm
(0.2 to 0.3 lbf ft)
Содержание ACS800-17LC
Страница 1: ...ABB industrial drives Hardware manual ACS800 17LC Drives 55 to 5200 kW ...
Страница 4: ......
Страница 10: ...Update notice 6 ...
Страница 18: ...Table of contents 12 ...
Страница 26: ...Safety instructions 20 ...
Страница 32: ...Introduction to the manual 26 ...
Страница 60: ...Hardware description 54 ...
Страница 74: ...Mechanical installation 68 ...
Страница 114: ...Electrical installation 108 ...
Страница 142: ...Maintenance 136 ...
Страница 150: ...Internal cooling circuit 144 ...
Страница 179: ...Dimensions 173 Frame sizes R7i R7i and R8i R8i bottom entry exit ...
Страница 180: ...Dimensions 174 Frame sizes R7i R7i and R8i R8i marine units C121 ...
Страница 182: ...www abb com drives www abb com drivespartners Contact us 3AUA0000065339 Rev B EN 2016 06 07 ...