The following table shows the values of selected DC voltage levels. Note that the
absolute voltages vary according to the drive/inverter type and AC supply voltage
range.
Settings
Parameters
(page
(page
),
(page
),
(page
) and
(page
Brake chopper
A brake chopper can be used to handle the energy generated by a decelerating
motor. When the DC voltage rises high enough, the chopper connects the DC circuit
to an external brake resistor. The chopper operates on the pulse width modulation
principle.
DC voltage level [V]
See
AC supply voltage range [V]
380…415
AC supply voltage range [V]
440…480
Overvoltage fault limit
840
840
Overvoltage control limit
780
780
Internal brake chopper start limit
780
780
Internal brake chopper stop limit
760
760
Overvoltage warning limit
745
745
Undervoltage warning limit
value
1)
0.85×1.41×par
value
1)
0.85×1.41×380 = 455
2)
0.85×1.41×440 = 527
2)
Undervoltage control limit
value
1)
0.75×1.41×par
value
1)
0.75×1.41×380 = 402
2)
0.75×1.41×440 = 465
2)
Charging relay closing limit
value
1)
0.75×1.41×par
value
1)
0.75×1.41×380 = 402
2)
0.75×1.41×440 = 465
2)
Charging relay opening limit
value
1)
value
1)
0.65×1.41×380 = 348
2)
0.65×1.41×440 = 403
2)
DC voltage at upper bound of supply
voltage range (
U
DCmax
)
560
648
DC voltage at lower bound of supply
voltage range (
U
DCmin
)
513
594
Charging activation/standby limit
3)
value
1)
0.65×1.41×par
value
1)
0.65×1.41×380 = 348
2)
0.65×1.41×440 = 403
2)
Undervoltage fault limit
value
1)
0.45×1.41×par
value
1)
0.45×1.41×380 = 241
2)
0.45×1.41×440 = 279
2)
1)
is set to
is
set to
, the value of parameter
is used,
2)
otherwise the lower limit of the range selected with parameter
is used.
3)
When standby is activated, drive modulation is stopped, the fan is stopped and the pre-charge circuit is
activated. If the voltage exceeds this level again, the drive has to complete charging before it will
automatically continue operation.
ACS580 FW.book Page 124 Wednesday, September 21, 2016 9:48 PM
Содержание ACS580 Series
Страница 88: ...84 ACS580 FW book Page 84 Wednesday September 21 2016 9 48 PM ...
Страница 146: ...142 Program features ACS580 FW book Page 142 Wednesday September 21 2016 9 48 PM ...
Страница 444: ...440 Fieldbus control through a fieldbus adapter ACS580 FW book Page 440 Wednesday September 21 2016 9 48 PM ...
Страница 461: ...ACS580 FW book Page 457 Wednesday September 21 2016 9 48 PM ...
Страница 462: ...3AXD0000016097 Rev D EN 2016 09 02 ACS580 FW book Page 458 Wednesday September 21 2016 9 48 PM ...