• If you cannot disconnect the motor, make sure that the motor cannot rotate during
work. Make sure that no other system, like hydraulic crawling drives, can rotate the
motor directly or through any mechanical connection like felt, nip, rope, etc.
• Do the steps in section
Electrical safety precautions (page 18)
• Install temporary grounding to the drive output terminals (T1/U, T2/V, T3/W). Connect
the output terminals together as well as to the PE.
During the start-up:
• Make sure that the motor cannot run overspeed, for example, driven by the load.
Motor overspeed causes overvoltage that can damage or destroy the capacitors in
the intermediate circuit of the drive.
■
Safety in operation
WARNING!
Make sure that the motor cannot run overspeed, for example, driven by the load.
Motor overspeed causes overvoltage that can damage or destroy the capacitors
in the intermediate circuit of the drive.
Safety instructions 21
Содержание ACS480-04-09A8-1
Страница 1: ... ABB GENERAL PURPOSE DRIVES ACS480 drives Hardware manual ...
Страница 2: ......
Страница 4: ......
Страница 14: ...14 ...
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 38: ...38 ...
Страница 44: ...44 ...
Страница 118: ...118 ...
Страница 126: ...126 ...
Страница 174: ...174 ...
Страница 176: ...Frame R0 Frame R0 front side IP20 UL open type 176 Dimension drawings ...
Страница 177: ... Frame R0 bottom rear IP20 UL open type Dimension drawings 177 ...
Страница 178: ...Frame R1 Frame R1 front side IP20 UL open type 178 Dimension drawings ...
Страница 179: ... Frame R1 bottom rear IP20 UL open type Dimension drawings 179 ...
Страница 180: ... Frame R1 front side UL Type 1 kit installed 180 Dimension drawings ...
Страница 181: ... Frame R1 bottom rear UL Type 1 kit installed Dimension drawings 181 ...
Страница 182: ...Frame R2 Frame R2 front side IP20 UL open type 182 Dimension drawings ...
Страница 183: ... Frame R2 bottom rear IP20 UL open type Dimension drawings 183 ...
Страница 184: ... Frame R2 front side UL Type 1 kit installed 184 Dimension drawings ...
Страница 185: ... Frame R2 bottom rear UL Type 1 kit installed Dimension drawings 185 ...
Страница 186: ...Frame R3 Frame R3 front side IP20 UL open type 186 Dimension drawings ...
Страница 187: ... Frame R3 bottom rear IP20 UL open type Dimension drawings 187 ...
Страница 188: ... Frame R3 front side UL Type 1 kit installed 188 Dimension drawings ...
Страница 189: ... Frame R3 bottom rear UL Type 1 kit installed Dimension drawings 189 ...
Страница 190: ...Frame R4 Frame R4 front side IP20 UL open type 190 Dimension drawings ...
Страница 191: ... Frame R4 bottom rear IP20 UL open type Dimension drawings 191 ...
Страница 192: ... Frame R4 front side UL Type 1 kit installed 192 Dimension drawings ...
Страница 193: ... Frame R4 bottom rear UL Type 1 kit installed Dimension drawings 193 ...
Страница 194: ...194 ...
Страница 221: ... Declarations of conformity The Safe torque off function 221 ...
Страница 231: ...Dimensions BIO 01 I O extension module 231 ...
Страница 232: ...232 ...
Страница 238: ...Dimensions 3AXD50000031148 rev A 238 BREL 01 relay output extension module ...